The MCO-170AIC incubator is designed for demanding and regulated applications in the biomedical, pharmaceutical, medical research and clinical laboratory. With a new touchscreen control panel that delivers improved usability, an optimized interior structure and technology for rapid cleaning, and proprietary infrared sensors for stabilizing temperature, CO2, and humidity levels, the cellIQTM CO2 series is the new generation of incubators for all your research needs.
Active Questions & AnswersAsk a Question
There are no current Discussions
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of MCO-170AICUV/MCO-170AICUVH
- Uniform Consistent Environment
- Rapid CO2 Recovery with IR2 Sensors
- New LCD Touch Screen for Improved Usability
- Easier to Clean and Maintain
- Condensation Management System for improved Humidity
- 3 Hour H2O2 Decontamination
- Active Background Decontamination Control with SafeCell UV and InCu-saFe®
- USB Log Function for Data Transfer and Storage
General Specifications
There are no General Specifications available.
Series Modals
PHCBi - MCO-170AICUV
[+] View Model SpecificationsDepth | 28.7 in |
Height | 35.4 in |
Internal Depth | 20.6 in |
Internal Height | 26.2 in |
Width | 24.4 in |
Internal Width | 19.3 in |
Chamber Volume | 165 L |
CO2 Range | 0 to 20 % |
Weight | 80 kg |
Additional Model Specifications | DATA ACQUISITION Data acquisition system (MTR-5000-PW)-Optional OUTER DOOR Painted Steel SHELVES 18.5" x 17.7" (470 x 450 mm) ACCESS PORT Inner Diameter: 30 mm (1.18 inch), on the back side INSULATION Extruded polystyrene foam HEATING METHOD DHA system (heater jacket + air jacket system) AIR FILTER 0.3 um, Efficiency: 99.97 % or higher UV LAMP 4W x 1 (ozone-free emission) TEMPERATURE CONTROL RANGE Ambient temperature +º5C to 50ºC (ambient temperature: 5ºC to 35ºC) TEMPERATURE UNIFORMITY ±0.25ºC (ambient temperature: 23ºC, setting: 37ºC, CO2: 5 %, no load) MAXIMUM POWER CONSUMPTION Max. 376 W CO2 CONTROLLER PID Control System CO2 GAS CONNECTION 4 mm to 6 mm (0.157 inch to 0.36 inch) diameter tube can be connected CO2 GAS PRESSURE 0.03 MPa(G) (0.3kgf/cm2(G),4.3 psi(G)) CO2 VARIATION ±0.15% (ambient temperature: 23ºC, setting: 37ºC, CO2: 5%, no load) CO2 SENSOR TYPE Dual Infrared Sensor DATA OUTPUT USB DECONTAMINATION METHODS H2O2 decontamination, UV decontamination SafeCell UV CONTAMINATION CONTROLS Standard 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) and Copper Alloy Interior Surface (InCu-saFe®) DECONTAMINATION CYCLE TIME < 3.0 Hours DISPLAY Color LCD touch panel HEATING SYSTEM DHA system (heater jacket + air jacket system) HUMIDIFYING SYSTEM Natural evaporation with humidifying pan, 95 %R.H.±5 %R.H. INTERIOR SURFACES InCu-saFe® Stainless steel containing copper |
PHCBi - MCO-170AICUVH
[+] View Model SpecificationsDepth | 28.7 in |
Height | 35.4 in |
Internal Depth | 20.6 in |
Internal Height | 26.2 in |
Width | 24.4 in |
Internal Width | 19.3 in |
Chamber Volume | 165 L |
CO2 Range | 0 to 20 % |
Weight | 80 kg |
Additional Model Specifications | DATA ACQUISITION Data acquisition system (MTR-5000-PW)-Optional INNER DOOR Tempered Glass SHELVES 18.5" x 17.7" (470 x 450 mm) ACCESS PORT Inner Diameter: 30 mm (1.18 inch), on the back side INSULATION Extruded polystyrene foam AIR FILTER 0.3 um, Efficiency: 99.97 % or higher UV LAMP 4W x 1 (ozone-free emission) TEMPERATURE CONTROL RANGE Ambient temperature +º5C to 50ºC (ambient temperature: 5ºC to 35ºC) TEMPERATURE UNIFORMITY ±0.25ºC (ambient temperature: 23ºC, setting: 37ºC, CO2: 5 %, no load) MAXIMUM POWER CONSUMPTION Max. 376 W CO2 CONTROLLER PID Control System CO2 GAS CONNECTION 4 mm to 6 mm (0.157 inch to 0.36 inch) diameter tube can be connected CO2 GAS PRESSURE 0.03 MPa(G) (0.3kgf/cm2(G),4.3 psi(G)) CO2 VARIATION ±0.15% (ambient temperature: 23ºC, setting: 37ºC, CO2: 5%, no load) CO2 SENSOR TYPE Dual Infrared Sensor DATA OUTPUT USB DECONTAMINATION METHODS H2O2 Vapor Decontamination CONTAMINATION CONTROLS Standard 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) and Copper Alloy Interior Surface (InCu-saFe®) DECONTAMINATION CYCLE TIME < 3.0 Hours DISPLAY Color LCD touch panel HEATING SYSTEM DHA system (heater jacket + air jacket system) HUMIDIFYING SYSTEM Natural evaporation with humidifying pan, 95 %R.H.±5 %R.H. |