Thermo Scientific - Varioskan Flash

Manufactured by  Thermo Scientific
Follow this Equipment

Varioskan® Flash spectral scanning multimode reader

The Thermo Scientific Varioskan Flash spectral scanning multimode reader is an ideal tool for speeding up assay development. It is designed for analysing and optimization of assays such as binding assays, ADMETox, molecular biology assays, enzyme kinetic studies, ion-channel and cell signalling assays.  
  
Varioskan® Flash includes fluorescence intensity, time-resolved fluorescence (TRF), photometric, and luminometric detection technologies. It provides optimal performance to speed up your assay development with unlimited wavelength selection, up to three onboard dispensers, unparalleled optical performance and the advanced SkanIt Software  
  
Varioskan Flash is certified for DLReady™ by Promega* and LanthaScreen™ by Invitrogen Corp**.  
  
Ordering Information:  
5250030: Varioskan Flash with top reading   
5250040: Varioskan Flash with top and Bottom reading   
5250500: Varioskan LumiSens option, factory fitted (also enabling luminometric spectral scanning)   
5250510: Dispenser option, with 1mL syringe, factory fitted
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked bySeraj

avatar placemark

Asked byDavidthomas

avatar placemark

Asked byjovitaponce

Microplate Readers Service ProvidersView All (12)

Request Support
Features of Varioskan Flash

Varioskan Flash spectral scanning multimode reader includes fluorescence intensity, time-resolved fluorescence (TRF), photometric, and optional luminometric detection technologies. It is designed for optimization and analysis of various assays, such as binding assays, ADMETox, molecular biology assays, enzyme kinetic studies, ion-channel and cell signaling assays.  

  • Unlimited wavelength selection for spectral analysis and measurement at any single wavelength—the optimal measurement wavelengths can be identified and easily selected for any assay at any time  
  • Extremely easy measurement setup with automated internal functions ensuring maximal sensitivity and full dynamic range for every assay  
  • Onboard dispensers for exact follow-up of kinetic reactions—essential for flash luminescence assays, Ca2+ flux studies and other rapid kinetic applications  
  • Increased assay throughput—reads up to 1536-well plates and can easily be integrated with automated systems  
  • High performance incubator for temperature critical assays  
  • Easy assay setup, flexible data handling and convenient report formatting with SkanIt Software
General Specifications

There are no General Specifications available.

Additional Specifications

Fluorescence Intensity/Time-Resolved Fluorescence  
Sample format: 6 – 1536-well plates  
Wavelength selection: Double excitation and double emission monochromators  
Excitation wavelength range: 200 – 1000 nm  
Emission wavelength range: 270 – 840 nm  
Excitation/emission bandwidth: 5 nm and 12 nm/12 nm  
Light source: Xenon flash lamp  
Sensitivity/dynamic range: Fluorescence intensity, top reading: 6 decades, 384-well plate  
Fluorescence intensity, bottom reading: 5.5 decades, 384-well plate  
Time-resolved fluorescence, top reading: 6 decades, 384-well plate  
  
Luminometry  
Sample format: 6 – 1536-well plates, spectral scanning 6 – 384-well plates  
Wavelength selection: All wavelengths, filters and double monochromators  
Wavelength range: 360 – 670 nm, spectral scanning 270 – 840 nm  
Sensitivity/dynamic range: 7 decades, flash ATP reaction, 384-well plate  
  
Photometry  
Sample format: 6 – 384-well plates  
Wavelength selection: Double monochromators  
Wavelength range: 200 – 1000 nm  
Bandwidth: 5 nm  
Light source: Xenon flash lamp  
Linear measurement range: 0 – 4 Abs (96-well plate) at 450 nm, ± 2%  
0 – 3 Abs (384-well plate) at 450 nm, ± 2%  
Accuracy: ± 2% or 0.003 Abs, whichever is greater, at 200 – 399 nm (0 – 2 Abs)  
± 1% or 0.003 Abs, whichever is greater, at 400 – 1000 nm (0 – 3 Abs)  
Precision: SD < 0.001 Abs or CV < 0.5%, whichever is greater, at 450 nm (0 – 3 Abs)  
  
Dispenser  
Number of dispensers: Up to 3, automatic dispensing position control  
Sample format: 6 – 384-well plates  
Syringe size: 1 ml (standard), 5 ml (on request)  
Dispensing volume 1 – 10 000 µl, with 1 µl increments (1 ml syringe)  
Automatic safety control based on maximum well volume  
Accuracy: < 0.2 µl or 2%, whichever is greater, 5 – 10 000 µl (1 ml syringe, 0.40 mm tip)  
Precision: 5 – 19 µl < 5%, 20 – 10 000 µl < 2% (1 ml syringe, 0.40 mm tip)  
Dispensing speed: 30 s for 96-well plate; 80 s for 384-well plate (5 µl/well, 1 ml syringe, 0.40 mm tip)  
  
Incubator: From ambient + 4°C to 45°C at ambient 25°C  
Shaker: Orbital with adjustable speed and diameter  
  
General Features  
Measurement modes: Endpoint, kinetic, spectral scanning with all detection technologies  
Measurement speed: 96-well plate in 15 s, 384-well plate in 45 s, and 1536-well plate in 135 s (minimum kinetic interval time from A1 back to A1)  
Spectral scanning speed: < 2 s/well, 400 – 500 nm, 1 flash, 2 nm steps

Series Modals

Thermo Scientific - FI/TRF Specifications

[+] View Model Specifications

Thermo Scientific - Luminometry Specifications

[+] View Model Specifications

Thermo Scientific - Photometry Specifications

[+] View Model Specifications
NewsView All Articles

Looking for

Thermo Scientific - Varioskan Flash?

Shop on LabX.com