Beckman Coulter - TOC PAT700

Manufactured by  Beckman Coulter
Follow this Equipment

TOC Analyzer Liquid Particle Counters

The PAT700 TOC analyzer fully complies with all global pharmacopeias (USP, EP, JP) requirements. Each sample is fully oxidized guaranteeing the most accurate TOC result that follows EP2.2.44 guidelines. Production uptime is assured with the PAT700 main and standby dual UV lamp design, making it the ideal choice for on-line TOC release. Save time and money - the PAT700 can be installed online and run up to 4 grab samples offline.
Active Questions & AnswersAsk a Question

There are no current Discussions

TOC Analyzers Service ProvidersView All (11)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of TOC PAT700

Have confidence in the data - assured with UV Detect, excursion alarming, and fully traceable calibration  Implement the FDA PAT initiative for on-line release for TOC and Conductivity eliminating time consuming and costly laboratory analysis. 

Reduce the risk of product recall and speed up water loop troublshooting when an excursion alarm occurs  The PAT700 internally captures two samples and then re-analyzes the first sample to validate the excursion alarm and saves the second sample for further root-cause analysis. 

Confirm production vessels are clean and ready to go on-line faster with Clean-in-Place (CIP) analysis  The PAT700 clean-in-place analysis maximizes production up-time by providing immediate on-line results for both TOC and conductivity. Providing instant on-line verification that your production vessel is ready for production changeover. 

Save hours and expand laboratory throughput with the PAT700 36 bottle auto-sampler  Using the ASX-7200 auto-sampler allows laboratory users to set up 36 bottles for TOC analysis and walk away. Using the PAT700 there is no requirement for costly reagents or carrier gases.

General Specifications

There are no General Specifications available.

Additional Specifications

TOC 
Operating Range 
0.5 to 2,000 ppb as Carbon 
Display Resolution 
0.1 ppd 
Accuracy 
+/-1 ppd or +/-5% whichever is greater 
Repeatability 
+/-0.3 ppd or +/-1% whichever is greater 
Limit of Detection 
0.5 ppb 
Maximum Input Conductivity 
0.2 uS/cm for all waters, 1.0 uS/cm for all neutral waters, 5.0 uS/cm for water with CO2 as the sole conductive species 
 
Conductivity 
Conductivity 
Range 0.05 to 150 uS/cm (@25* C) 
Display Resolution 
0.01 uS/cm 
Conductivity Accuracy 
+/-2% over full range (uncompensated) 
Resistivity 
Resistivity Range 0.2 to 18 MQ-cm (@25*C) 
Display Resolution 
0.01 over full range 
Available Modes 
Temperature compensated to 25*C, or uncompensated 
 
Temperature 
Ambient Operating Range 
10 to 40*C (50 to 104*F) 
Measurement Accuracy 
+/-0.4*C 
Sample Water Range 
5 to 95*C (41 to 203*F) 
Display Resolution 
0.1 over full range 
 
Physical Specs 
UV Lamps 
2, with UV Detect technology 
Interface/Display 
Color with touch screen 
Maximum Altitude 
4,000 m (13,125) 
User I/O Wiring 
Three, 3/4-inch conduit openings or quick disconnect fittings 
Standards System 
Onboard, Automated Standards Introduction System (OASIS) 
Dimensions 
59.7 w X 22.9 d X 25.4 h (23.5 X 9 X 10 inches) 
Weight 
13.6 kg (30 lbs) 
Sample Inlet Flow Rate Range 
60 mL/min to 300 mL/min 
Sample Inlet Pressure Range 
10 to 100 psi (69 to 690 kPa) 
 
Compliance 
Installation Category 
II 
Pollution Degree 
2, IEC 61010-1 
CE Compliance 
EN 61010-1 and EN 61326 
Safety Rating 
ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1 
Enclosure Rating 
Conduit version: IP56 Quick connect version: IP46 
Release Tests 
USP , USP , JP 16, EP 2.2.44 
 
New Features 
CIP 
Selectable mode for Clean-In-Place analysis 
Dual Stream option 
Toggle or programmable stream switching 
Excursion sampling 
Minimum flow rate to fill excursion bottle = 160 mL/min 
Rouge detection 
Identifies oxidation cell contamination from roughing