LabLogic Systems - Flow-RAM™
Manufactured by LabLogic Systems
Flow-RAM is the new and compact radio HPLC detector for PET and SPECT applications.
LabLogic’s innovative Flow-RAM is a gamma radio HPLC detector specifically developed for PET and SPECT applications – the company’s response to five years’ feedback from customers in PET centres and nuclear medicine departments.
Flow-RAM is available in different configurations whereby either one or two detectors can be connected to the system at any one time. The two-detector configuration accepts two detectors - different or the same - that work simultaneously yet independently of one another. This creates a ‘two in one’ instrument, giving exceptional flexibility, hence saving space and money.
The user can lock down features such as the high voltage, upper and lower level discriminators to prevent unauthorised adjustments to specified radionuclide operating parameters, ensuring consistent GLP/GMP compliance.
Power supply, instrument control and data collection is via a single USB connection. Full control of the Flow-RAM is provided by LabLogic’s market-leading Laura radiochromatography software. In addition, for those wishing to use the detector with their existing chromatography system, the Flow-RAM offers stand-alone control through a pocket digital assistant over a Bluetooth wireless link.
To optimise Flow-RAM’s performance, LabLogic offers an extensive range of detectors - NaI/PMT, plastic scintillator/PMT, well type NaI/PMT, pin diode, etc – and can advise on the most suitable type for every application. Also available is bespoke lead shielding to suit the needs of laboratories with varying levels of background radioactivity.
Flow-RAM is available in different configurations whereby either one or two detectors can be connected to the system at any one time. The two-detector configuration accepts two detectors - different or the same - that work simultaneously yet independently of one another. This creates a ‘two in one’ instrument, giving exceptional flexibility, hence saving space and money.
The user can lock down features such as the high voltage, upper and lower level discriminators to prevent unauthorised adjustments to specified radionuclide operating parameters, ensuring consistent GLP/GMP compliance.
Power supply, instrument control and data collection is via a single USB connection. Full control of the Flow-RAM is provided by LabLogic’s market-leading Laura radiochromatography software. In addition, for those wishing to use the detector with their existing chromatography system, the Flow-RAM offers stand-alone control through a pocket digital assistant over a Bluetooth wireless link.
To optimise Flow-RAM’s performance, LabLogic offers an extensive range of detectors - NaI/PMT, plastic scintillator/PMT, well type NaI/PMT, pin diode, etc – and can advise on the most suitable type for every application. Also available is bespoke lead shielding to suit the needs of laboratories with varying levels of background radioactivity.
Active Questions & AnswersAsk a Question
There are no current Discussions
Radiochemical Detector Service ProvidersView All (21)
Documents & ManualsView All Documents
Features of Flow-RAM™
- GLP/GMP compliance as standard
- A wide range of detectors for all Nuclear Medicine and PET Radionuclides
- Bespoke lead shielding to limit the background interference
- Intelligent and informative front end display
- Flexibility; two detectors can be connected to the same instrument simultaneously AND independently of one another to provide a two in one instrument
- USB connection for power supply, instrument control and data collection, rather than the now outdated and slow serial output of older systems
- Flow-RAM is the first radiodetector of its type to offer stand alone control of data collectionthrough a pocket digital assistant via a Bluetooth™ wireless link.