Teledyne Technologies - Z-2000 Series
Manufactured by Teledyne Technologies
Polarized Zeeman Atomic Absorption Spectrophotometer
Easier Operation, More Reliable Analyses and Higher Sensitivity. This is the concept of Z-series polarized Zeeman AAS. Three models are available to meet your specific needs.
High Quality: Excellent Sensitivity using Zeeman Method and Dual Detector.
Compact: Installation Space is Reduced (Z-2300/2700)
Useful Design: Slim design with built-in Graphite Furnace Autosampler
New optics and improved graphite furnace power supply circuit enhance sensitivity. Using common hollow cathode lamps, Z-2000 Series spectrophotometer is capable of analyzing As, Se and Sb in tap water and environmental water, which previously have only been measurable by using EDL (high-intensity) lamps in conventional graphite furnace analyses.
High Quality: Excellent Sensitivity using Zeeman Method and Dual Detector.
Compact: Installation Space is Reduced (Z-2300/2700)
Useful Design: Slim design with built-in Graphite Furnace Autosampler
New optics and improved graphite furnace power supply circuit enhance sensitivity. Using common hollow cathode lamps, Z-2000 Series spectrophotometer is capable of analyzing As, Se and Sb in tap water and environmental water, which previously have only been measurable by using EDL (high-intensity) lamps in conventional graphite furnace analyses.
Active Questions & AnswersAsk a Question
1Replies
Enquiry Ref. No. 1402
1Replies
AAS Fuel pressure
Need Equipment Support?
Documents & ManualsView All Documents
Features of Z-2000 Series
Model Z-2000 TANDEM TYPE ATOMIC ABSORPTION SPECTROPHOTOMETER
- The polarized Zeeman method featuring low noise and high stability is adopted for both flame and graphite furnace methods.
- Highly accurate analysis is achievable with no need for moving sample compartment or adjusting optics.
Model Z-2300 FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER
- The polarized Zeeman method featuring low noise, high stability and high throughput is adopted for the flame method.
- Easy operation is supported by Analysis Assist, Real-time QC and Easy Start functions.
Model Z-2700 GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROPHOTOMETER
- Highly accurate background correction is possible by Direct Current (DC) polarized Zeeman method.
- Integrated design with autosampler and dustproof cover.
General Specifications
There are no General Specifications available.
Series Modals
Hitachi Medical Systems - Z-2000
[+] View Model SpecificationsDepth | 63 cm |
Graphite Furnace | 1 |
Height | 70 cm |
Lamps | 8 Lamps(turret), 2 Lamps simultaneous lighting |
Width | 110 cm |
Power Requirements | 220/230/240 V, 50/60 Hz |
Peak Power | 6000 VA |
Optical System | Double-beam method |
Weight | 189 kg |
Zeeman | 1 |
Wavelength Range | 190 to 900 nm |
Additional Model Specifications | Analytical method: Flame/Graphite furnace Measurement mode: Atomic absorption and flame phtometry Background correction: Polarized Zeeman method Monochromator Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm) Light source Lamp position control: Automatic position setting, fine adjustment function Flame part: Zeeman-effect magnet: 0.9 Tesla permanent magnet Burner: Pre-mixed fish-tail type Ignition method: Pilot flame automatic ignition Combustion condition setting: Automatic flow rate setting of combustion gas Safety monitoring function: Optical flame monitoring, flame sensor error detection, fuel/auxiliary gas pressure monitoring, drain liquid level monitoring, cooling water flow monitoring, flash-back shock absorption, safety flame extinguishing at power failure (buffer tank method), N2O select safety mechanism, etc. Graphite furnace part Zeeman-effect magnet: 1.0 Tesla permanent magnet Temperature control: 50 to 2,800, over current protection Heating current control: Optical temperature control, constant current control Gas flow rate control: Sheath gas: Ar gas; 3 L/min. Carrier gas: Ar gas; 0, 10, 30, 200 mL/min.(4 steps) Safety monitoring control: Ar gas pressure monitoring, cooling water flow monitoring, furnace temperature monitoring Graphite furnace autosampler Number of sample containers: 60 pcs (1.5 mL container), 96-well micro plate [option] Modifier container: 5 pcs(25 mL container) Sample injection volume: 1 to 100µL Sample injection reproducibility: RSD 1% or less (5 to 100µL) Sample injection speed: Selectable in 5 steps Rinse solution discharge: 1 mL Applicable solvents: Aqueous solution, ethanol, methanol, acetone, MIBK Carry-over: 10^-5 or less (for standard aqueous solution sample) Heating injection function: Yes Number of nozzle washing: 5 times Sample condensation (in furnace): 1 to 25 times Sample dilution (in furnace): 1 to 10 times |
Hitachi Medical Systems - Z-2300
[+] View Model SpecificationsDepth | 63 cm |
Graphite Furnace | 0 |
Height | 70 cm |
Lamps | 8 Lamps(turret), 2 Lamps simultaneous lighting |
Width | 75 cm |
Power Requirements | 115/220/230/240 V, 50/60 Hz |
Peak Power | 200 VA |
Optical System | 8 Lamps(turret), 2 Lamps simultaneous lighting |
Weight | 106 kg |
Zeeman | 1 |
Wavelength Range | 190 to 900 nm |
Additional Model Specifications | Analytical method: Flame Measurement mode: Atomic absorption and flame phtometry Background correction: Polarized Zeeman method Monochromator Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm) Light source Lamp position control: Automatic position setting, fine adjustment function Flame part: Zeeman-effect magnet: 0.9 Tesla permanent magnet Burner: Pre-mixed fish-tail type Ignition method: Pilot flame automatic ignition Combustion condition setting: Automatic flow rate setting of combustion gas Safety monitoring function: Optical flame monitoring, flame sensor error detection, fuel/auxiliary gas pressure monitoring, drain liquid level monitoring, cooling water flow monitoring, flash-back shock absorption, safety flame extinguishing at power failure (buffer tank method), N2O select safety mechanism, etc. |
Hitachi Medical Systems - Z-2700
[+] View Model SpecificationsDepth | 63 cm |
Graphite Furnace | 1 |
Height | 70 cm |
Lamps | 8 Lamps(turret), 2 Lamps simultaneous lighting |
Width | 75 cm |
Power Requirements | 220/230/240 V, 50/60 Hz |
Peak Power | 6000 VA |
Optical System | Double-beam method |
Weight | 139 kg |
Zeeman | 1 |
Wavelength Range | 190 to 900 nm |
Additional Model Specifications | Analytical method: Graphite furnace Measurement mode: Atomic absorption spectrometry Background correction: Polarized Zeeman method Monochromator Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm) Light source Lamp position control: Automatic position setting, fine adjustment function Graphite furnace part Zeeman-effect magnet: 1.0 Tesla permanent magnet Temperature control: 50 to 2,800, over current protection Heating current control: Optical temperature control, constant current control Gas flow rate control: Sheath gas: Ar gas; 3 L/min. Carrier gas: Ar gas; 0, 10, 30, 200 mL/min.(4 steps) Safety monitoring control: Ar gas pressure monitoring, cooling water flow monitoring, furnace temperature monitoring Graphite furnace autosampler Number of sample containers: 60 pcs (1.5 mL container), 96-well micro plate [option] Modifier container: 5 pcs(25 mL container) Sample injection volume: 1 to 100µL Sample injection reproducibility: RSD 1% or less (5 to 100µL) Sample injection speed: Selectable in 5 steps Rinse solution discharge: 1 mL Applicable solvents: Aqueous solution, ethanol, methanol, acetone, MIBK Carry-over: 10^-5 or less (for standard aqueous solution sample) Heating injection function: Yes Number of nozzle washing: 5 times Sample condensation (in furnace): 1 to 25 times Sample dilution (in furnace): 1 to 10 times |