Thermo Scientific - iCE 3000 Series
All iCE 3000 Series spectrometers are completely automatic with full element capability. Control is via a data station...
Active Questions & AnswersAsk a Question
Need Equipment Support?
Documents & ManualsView All Documents
Features of iCE 3000 Series
iCE 3500
Dual atomizer AA spectrometer
Flame atomization in left hand sample compartment
Furnace atomization in the right hand sample compartment
Vapour atomization in either sample compartment
Zeeman or non-Zeeman furnace options
Wide range photomultiplier
Furnace vision system as standard
iCE 3400
Zeeman furnace
Wide range photomultiplier
6 lamp auto-aligning carousel
Furnace or vapour atomization
Furnace vision system as standard
iCE 3300
Standard or wide range photomultiplier
6 lamp auto-aligning carousel
Fully automatic gas system
General Specifications
There are no General Specifications available.
Additional Specifications
Optics: Double beam
Monochromator: Ebert type
Lamp Carousel: Lamp coded, auto-aligning 6-lamp turret
Photomultiplier: Wide range
Flame Atomizer: Universal system (uses 50mm Ti burner)
Background Correction: Guaranteed Quadline deuterium system
Gas Management: Automatic
PC Software: Included as standard
Furnace Atomizer Option: GFS33 combined module
Series Modals
Thermo Scientific - iCE 3300
[+] View Model SpecificationsDepth | 595 mm |
Graphite Furnace | 0 |
Height | 527 mm |
Lamps | 6 lamp auto-aligning carousel |
Width | 575 mm |
Power Requirements | 100 to 240 V (+/-10 %) at 50 or 60 Hz |
Peak Power | 300 VA |
Optical System | Double beam |
Wavelength Range | 180 to 900 nm |
Additional Model Specifications | Monochromator: Ebert Spectral Bandwidths: Nominal 0.2, 0.5 and 1.0 nm Reciprocal linear dispersion: 1.5 to 2 nm/mm Focal Length: 270 nm Grating: 1800 l/mm |
Thermo Scientific - iCE 3400
[+] View Model SpecificationsDepth | 595 mm |
Graphite Furnace | 0 |
Height | 527 mm |
Lamps | Double beam |
Width | 788 mm |
Power Requirements | 100 to 240 V (+/-10 %) at 50 or 60 Hz |
Peak Power | 300 VA |
Optical System | Self referencing Zeeman System |
Wavelength Range | 180 to 900 nm |
Additional Model Specifications | Monochromator and Prism: Echelle Spectral Bandwidths: Nominal 0.1 (available below 400 nm), 0.2, 0.5, and 1.0 nm Reciprocal linear dispersion: 0.5 nm/mm at 200 nm |
Thermo Scientific - iCE 3500
[+] View Model SpecificationsDepth | 595 mm |
Graphite Furnace | 0 |
Height | 527 mm |
Width | 788 mm |
Power Requirements | 100 to 240 V (+/-10 %) at 50 or 60 Hz |
Peak Power | 300 VA |
Optical System | Double beam, Stockdale optics |
Wavelength Range | 180 to 900 nm |
Additional Model Specifications |