Analytik Jena - multi N/C®
Manufactured by Analytik Jena
The high performance TOC analyzers: routine and specialist tool for any application, in particular for pharmaceutical applications
The TOC/TNb analyzers of the multi N/C® series set new standards!
The parameters TOC, NPOC, POC, TC, TIC and TNb can be easily measured precisely, fast and reliably. multi N/C® is the ideal system for routine applications, such as the examination of drinking and waste water, or special applications, such as pharmaceutical purification validation.
The modular versatility and comprehensive range of accessories guarantee for every user an individual adaptation to the respective requirements. The fast readiness for operation, easy handling and long-lasting components make every model within the series to an ideal partner during daily practice.
The parameters TOC, NPOC, POC, TC, TIC and TNb can be easily measured precisely, fast and reliably. multi N/C® is the ideal system for routine applications, such as the examination of drinking and waste water, or special applications, such as pharmaceutical purification validation.
The modular versatility and comprehensive range of accessories guarantee for every user an individual adaptation to the respective requirements. The fast readiness for operation, easy handling and long-lasting components make every model within the series to an ideal partner during daily practice.
Active Questions & AnswersAsk a Question
2Replies
NPOC method
TOC Analyzers Service ProvidersView All (11)
Documents & ManualsView All Documents
Features of multi N/C®
- Large measuring range – even without sample dilution: precise detection due to the high quality Focus Radiation NDIR Detector® (FR NDIR Detector) for TOC, Chemoluminescence detector (CLD) or solid state chemical detector (ChD) for TNb
- VITA® Flow Management System: for stable equipment performance and highly reproducible analysis results
- Easy Cal®: easiest calibration with only one standard for the most varied applications, including longterm stability
- Auto-protection: effective measuring gas purification and monitoring protect high quality system components
- Reliable oxidation: high temperature incineration (up to 950ºC) or High power UV reactor
- Variable injection technologies: valve-free direct injection or flow injection
- Variable injection volumes
- TC, TOC, TIC, NPOC and NPOC plus, POC, TNb: multiple parameter detection
- Suitable for the simultaneous TNb detection
- Solids analysis at the highest level: Double furnace technology — the ideal combination for water and solid samples without additional furnace
- Self Check System (SCS) for optimum operational and analytic safety
- Automation and modular principle: multitude of analyzers and accessories tailored for your application
General Specifications
There are no General Specifications available.
Series Modals
Analytik Jena - multi N/C® 2100
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 1 to 30000 mg/L |
Sample Volume Range | 50 to 500 μL |
Detection Limit | 200 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 VA |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: High temperature combustion up to 950°C Detection of CO2: Focus Radiation NDIR detector® Control by: PC Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Optional parameters: TN (ChD or CLD) Measurement accuracy (reproducibility): CV 2-3% Sample injection: direct injection Special features: Auto-protection, Self Check System TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: no Required gas: synthetic air or oxygen Gas consumption: approx. 1800 l/month (calculated for 8 hours/day x 5 days/week operation) Upgrade for solid samples: Double furnace solid module or HT 1300 Sampler options: APG 60 Included Software: PC software multiWin® |
Analytik Jena - multi N/C® 2100S
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 0 to 30000 mg/L |
Sample Volume Range | 50 to 500 μL |
Detection Limit | 50 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 VA |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: High temperature combustion up to 950°C Detection of CO2: Focus Radiation NDIR detector® Control by: PC or stand alone option Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Optional parameters: TN (ChD or CLD) Measurement accuracy (reproducibility): CV 1-2% Sample injection: Septum-free direct injection Injection volume: 50 – 500µl variable Special features: VITA® Flow Management System, Auto-protection, Self Check System (SCS), Easy Cal® TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: yes Required gas: synthetic air or oxygen Gas consumption: approx. 1800 l/month (calculated for 8 hours/day x 5 days/week operation) Upgrade for solid samples: Double furnace solid module or HT 1300 Sampler options: APG 60 Included Software: PC software multiWin® Software Options: Stand alone software (included in SA-Option) |
Analytik Jena - multi N/C® 3100
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 1 to 30000 mg/L |
Sample Volume Range | 100 to 1000 μL |
Detection Limit | 4 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 mW |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: High temperature combustion up to 950°C Detection of CO2: Focus Radiation NDIR detector® Control by: PC or stand alone option Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Optional parameters: TN (ChD or CLD), POC direct Measurement accuracy (reproducibility): CV 1-2% Sample injection: Automatic flow injection with intelligent rinsing Special features: VITA® Flow Management System, Auto-protection, Self Check System (SCS), Easy Cal® TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: yes Automatic dilution: Dilution factor 2 up to 100 Required gas: synthetic air or oxygen Gas consumption: approx. 2200 l/month (calculated for 8 hours/day x 5 days/week operation) Upgrade for solid samples: HT 1300 Sampler options: APG 10, APG 21, APG 64, EPA Included Software: PC software multiWin® Software Options: Stand alone software (included in SA-Option) |
Analytik Jena - multi N/C® pharma HT
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 1 to 10000 mg/L |
Sample Volume Range | 50 to 30000 μL |
Detection Limit | 4 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 VA |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: High temperature combustion up to 950°C Detection of CO2: Focus Radiation NDIR detector® Control by: PC Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Optional parameters: TN (CLD) Measurement accuracy (reproducibility): CV 1-2% Sample injection: Automatic flow injection Special features: VITA® Flow Management System, Auto-protection, Self Check System (SCS), Easy Cal® TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: yes Required gas: oxygen Gas consumption: approx. 1400 l/month (calculated for 8 hours/day x 5 days/week operation) Upgrade for solid samples: Swab test module Sampler options: APG 10, APG 21, APG 49, EPA sampler Included Software: Pharma PC software multiWin® |
Analytik Jena - multi N/C® pharma UV
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 0 to 10000 mg/L |
Sample Volume Range | 50 to 20000 μL |
Detection Limit | 2 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 VA |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: Wet chemical oxidation by UV (254nm+185 nm) / persulfate Detection of CO2: Focus Radiation NDIR detector® Control by: PC Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Measurement accuracy (reproducibility): CV 1-2% Sample injection: Automatic flow injection Special features: VITA® Flow Management System, Auto-protection, Self Check System (SCS), Easy Cal® TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: yes Required gas: nitrogen Gas consumption: approx. 2200 l/month (calculated for 8 hours/day x 5 days/week operation) Sampler options: APG 10, APG 21, APG 49, EPA sampler Included Software: Pharma PC software multiWin® |
Analytik Jena - multi N/C® UV HS
[+] View Model SpecificationsDepth | 550 mm |
Measurement Range | 1 to 10000 mg/L |
Sample Volume Range | 50 to 20000 μL |
Detection Limit | 2 µg/L |
Height | 464 mm |
Width | 513 mm |
NDIR | 1 |
Power Requirements | 115/230 V; 50/60 Hz; 10A/ 6.3A |
Peak Power | 1000 VA |
Weight | 30 kg |
Measurement Time | approx. 3- 5 min for each parameter |
Portable | 0 |
Additional Model Specifications | Digestion mode: Wet chemical oxidation by UV (254nm+185 nm) / persulfate Detection of CO2: Focus Radiation NDIR detector® Control by: PC Parameters: TC, TIC, TOC, NPOC, NPOC plus, POC (indirect measurement) Measurement accuracy (reproducibility): CV 1-2% Sample injection: Automatic flow injection Special features: VITA® Flow Management System, Auto-protection, Self Check System (SCS), Easy Cal® TIC elimination for NPOC mode: acidification and purging + TIC control measurement Automatic system tightness control: yes Required gas: nitrogen Gas consumption: approx. 2200 l/month (calculated for 8 hours/day x 5 days/week operation) Upgrade for solid samples: HT 1300 Sampler options: APG 10, APG 21, APG 49, EPA sampler Included Software: PC software multiWin® |