BINDER - KBF LQC series
Manufactured by BINDER
Constant climate chambers with Light Quantum Control
The special advantage of BINDER KBF LQC series: the patented photometry for photostability testing. Two spherical 3D ball-type sensors capture visible light intensity and UV light intensity – if the desired light dosage is achieved, it switches off automatically.
Active Questions & AnswersAsk a Question
There are no current Discussions
Environmental Chambers Service ProvidersView All (20)
Documents & ManualsView All Documents
Features of KBF LQC series
- Electronically controlled APT.line™ preheating chamber with cooling system assuring temperature accuracy and reproducible results
- 2 variable position illumination cassettes with BINDER Q1B Synergy Light™ for unique homogeneous light distribution over the entire usable area
- Illumination is suitable for stability in accordance with ICH guideline Q1B, option 2
- Light Quantum Control LQC, precise light intensity measurement, directly at the sample location using ball-type sensors
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User-friendly LCD screen -Easy-to-read menu guide -Integrated electronic chart recorder -Variety of options for the graphic display of process parameters -Real-time clock
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A (R2)
- Inner glass door with seal
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Access port with silicone plug Ø 30 mm, left side
- Complete safety connection kit for water supply and drainage, including water hose, (total length 6 m)
- Ethernet interface for communication software APT-COM™ DataControlSystem
- 2 shelves, stainless steel
- BINDER test certificate
General Specifications
There are no General Specifications available.
Series Modals
BINDER - KBF LQC 240
[+] View Model SpecificationsDepth | 800 mm (plus door handle, I-panel, connection 50 mm) |
Height | 1460 mm (incl. castors) |
Width | 925 mm |
Weight | 213 kg |
Additional Model Specifications | Interior dimensions Width (mm): 650 Height (mm): 785 Depth (mm): 485 Interior volume (l): 247 Racks (number standard/max.): 2 / 7 Load per rack (kg): 30 Permitted total load (kg): 100 Temperature data (without humidity) without illumination cassettes (°C) 1): 0 - 70 with illumination cassettes, with illumination (°C) 1): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 400 Climate data (with humidity) Temperature range without illumination cassettes (°C) 1): 10 - 70 Temperature range with illumination cassettes with illumination (°C) 1): 10 - 60 Temperature variation with illumination: at 25 °C and 60% RH (± K): 0,6 at 40 °C and 75% RH (± K): 0,6 Temperature fluctuation with illumination: at 25 °C and 60% RH (± K): 0,2 at 40 °C and 75% RH (± K): 0,2 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination 1) (°C): 10 - 75 Humidity fluctuation with illumination at 25 °C and 60% RH (± % RH): 1,5 at 40 °C and 75% RH (± % RH): 2 Recovery time after doors were open for 30 sec.: at 25 °C and 60% RH with illumination (min.): 3 at 40 °C and 75% RH with illumination (min.): 4 Illumination data per light cassette: ICH-compliant illumination device for photostability testing (Lux) / (UVA W/m²): 7500 / 1,4 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 2,4 Energy consumption at 40 °C / 75% RH 1) (W): 600 Noise level approx. (dB (A)): 52 |
BINDER - KBF LQC 720
[+] View Model SpecificationsDepth | 890 mm |
Height | 1925 mm |
Width | 1250 mm |
Weight | 374 kg |
Additional Model Specifications | Interior dimensions Width (mm): 973 Height (mm): 1250 Depth (mm): 576 Interior volume (l): 700 Racks (number standard/max.): 3 / 12 Load per rack (kg): 45 Permitted total load (kg): 150 Temperature data (without humidity) without illumination cassettes (°C) 1): 0 - 70 with illumination cassettes, with illumination (°C) 1): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 1000 Climate data (with humidity) Temperature range without illumination cassettes (°C) 1): 10 - 70 Temperature range with illumination cassettes with illumination (°C) 1): 20 - 60 Temperature variation with illumination: at 25 °C and 60% RH (± K): 1,2 at 40 °C and 75% RH (± K): 1,2 Temperature fluctuation with illumination: at 25 °C and 60% RH (± K): 0,2 at 40 °C and 75% RH (± K): 0,2 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination 1) (°C): 10 - 75 Humidity fluctuation with illumination at 25 °C and 60% RH (± % RH): at 25 °C and 60% RH (± % RH): 2 at 40 °C and 75% RH (± % RH): 2 Recovery time after doors were open for 30 sec.: at 25 °C and 60% RH with illumination (min.): 1 at 40 °C and 75% RH with illumination (min.): 5 Illumination data per light cassette: ICH-compliant illumination device for photostability testing (Lux) / (UVA W/m²): 9000 / 2,1 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 3,5 Energy consumption at 40 °C / 75% RH 1) (W): 2350 Noise level approx. (dB (A)): 53 |