The BINDER KBF P, equipped with ICH-compliant illumination, is the expert for photostability testing and provides clear and meaningful test results according to ICH guideline Q1B, Option 2. At the same time, the variable position illumination cassettes with BINDER Q1B Synergy™ Light ensure homogeneous lighting conditions.
Active Questions & AnswersAsk a Question
There are no current Discussions
Environmental Chambers Service ProvidersView All (20)
Documents & ManualsView All Documents
Features of KBF P series
- Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
- 2 variable position illumination cassettes with BINDER Q1B Synergy Light™ for unique homogeneous light distribution over the entire usable area
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User-friendly LCD screen -Easy-to-read menu guide -Integrated electronic chart recorder -Variety of options for the graphic display of process parameters -Real-time clock
- Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A (R2)
- Inner glass door with seal
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Access port with silicone plug Ø 30 mm, left side
- Complete safety connection kit for water supply and drainage, including water hose, (total length 6 m)
- Ethernet interface for communication software APT-COM™ DataControlSystem
- 2 shelves, stainless steel
- BINDER test certificate
General Specifications
There are no General Specifications available.
Series Modals
BINDER - KBF P 240
[+] View Model SpecificationsDepth | 800 mm |
Height | 1460 mm (incl. casters) |
Width | 925 mm |
Weight | 213 kg |
Additional Model Specifications | Interior dimensions Width (mm): 650 Height (mm): 785 Depth (mm): 485 Interior volume (l): 247 Racks (number standard/max.): 2 / 7 Load per rack (kg): 30 Permitted total load (kg): 100 Temperature data (without humidity) without illumination cassettes (°C) 1): 0 - 70 with illumination cassettes, with illumination (°C) 1): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 400 Climate data (with humidity) Temperature range without illumination cassettes (°C) 1): 10 - 70 Temperature range with illumination cassettes with illumination (°C) 1): 10 - 60 Temperature variation with illumination: at 25 °C and 60% RH (± K): 0,6 at 40 °C and 75% RH (± K): 0,6 Temperature fluctuation with illumination: at 25 °C and 60% RH (± K): 0,2 at 40 °C and 75% RH (± K): 0,2 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination 1) (°C): 10 - 75 Humidity fluctuation with illumination: at 25 °C and 60% RH (± % RH): 1,5 at 40 °C and 75% RH (± % RH): 2 Recovery time after doors were open for 30 sec.: at 25 °C and 60% RH with illumination (min.): 3 at 40 °C and 75% RH with illumination (min.): 4 Illumination data per light cassette ICH-compliant illumination device for photostability testing (Lux) / (UVA W/m²): 7500 / 1,4 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 2,4 Energy consumption at 40 °C / 75 % RH 1) (kW): 0,6 Noise level approx. (dB (A)): 52 |
BINDER - KBF P 720
[+] View Model SpecificationsDepth | 890 mm |
Height | 1925 mm (incl. casters) |
Width | 1250 mm |
Weight | 374 kg |
Additional Model Specifications | Interior dimensions Width (mm): 973 Height (mm): 1250 Depth (mm): 576 Interior volume (l): 700 Racks (number standard/max.): 3 / 12 Load per rack (kg): 45 Permitted total load (kg): 150 Temperature data (without humidity) without illumination cassettes (°C) 1): 0 - 70 with illumination cassettes, with illumination (°C) 1): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 1000 Climate data (with humidity) Temperature range without illumination cassettes (°C) 1): 0 - 70 Temperature range with illumination cassettes with illumination (°C) 1): 20 - 60 Temperature variation with illumination: at 25 °C and 60% RH (± K): 1,2 at 40 °C and 75% RH (± K): 1,2 Temperature fluctuation with illumination: at 25 °C and 60% RH (± K): 0,2 at 40 °C and 75% RH (± K): 0,2 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination 1) (°C): 10 - 75 Humidity fluctuation with illumination: at 25 °C and 60% RH (± % RH): 2 at 40 °C and 75% RH (± % RH): 2 Recovery time after doors were open for 30 sec.: at 25 °C and 60% RH with illumination (min.): 1 at 40 °C and 75% RH with illumination (min.): 5 Illumination data per light cassette ICH-compliant illumination device for photostability testing (Lux) / (UVA W/m²): 9000 / 2,1 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 3,5 Energy consumption at 40 °C / 75 % RH 1) (kW): 2,35 Noise level approx. (dB (A)): 53 |