BINDER - KBWF series
Manufactured by BINDER
Climate chambers with illumination and humidity
The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from above. It creates consistent climate conditions – even with illumination.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Environmental Chambers Service ProvidersView All (20)
Documents & ManualsView All Documents
Features of KBWF series
- Electronically controlled APT.line™ preheating chamber with cooling system assuring temperature accuracy and reproducible results
- Temperature range 0 °C to 70 °C (without humidity and illumination)
- Temperature range 10 °C to 60 °C (with humidity and illumination)
- Humidity range 10% to 80% RH (without illumination)
- Humidity range 10% to 75% RH (with illumination)
- 2 variable position illumination cassettes each with 5 daylight fluorescent illumination tubes
- 2 racks, stainless steel
- Patented light system for unique homogeneous light distribution over the entire usable area
- MCS controller for temperature, humidity, and lighting control with 25 storable programs of 100 sections each for a maximum of 500 program segments, for programming of day/night cycles
- Integrated electronic chart recorder -Variety of options for the graphic display of process parameters -Real-time clock
- Controlled humidification and dehumidification system with capacitive humidity sensor
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Access port with silicone plug Ø 30 mm, left side
- Inner glass door
- Complete safety connection kit for water supply and drainage, including water hose, (total length 6 m)
- RS 422 interface for communication software APT-COM™ DataControlSystem
- BINDER test certificate
General Specifications
There are no General Specifications available.
Series Modals
BINDER - KBWF 240
[+] View Model SpecificationsDepth | 800 mm (plus 50 mm door handle, I-triangle, connection) |
Height | 1460 mm (incl. casters) |
Width | 925 mm |
Weight | 214 kg |
Additional Model Specifications | Interior dimensions Width (mm): 650 Height (mm): 785 Depth (mm): 485 Interior volume (l): 247 Racks (number standard/max.): 2 / 7 Load per rack (kg): 30 Permitted total load (kg): 100 Variable position illumination cassettes: 2 Temperature data (without humidity) Temperature range without illumination cassettes (°C): 0 - 70 Temperature range with illumination cassettes with illumination (°C): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 400 Climate data (with humidity) Temperature range without illumination cassettes (°C): 10 - 70 Temperature range with illumination cassettes with illumination (°C): 10 - 60 Temperature variation with illumination (± K): 0,5 - 1,0 Temperature fluctuation with illumination (± K): 0,1 - 0,5 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination (% RH): 10 - 75 Humidity fluctuation with illumination (± % RH): 2 Illumination data per light cassette Daylight tubes (Lux): 10000 Daylight tubes (W/m²): 36 Fluora® growth lamps (Lux): 6500 Fluora® growth lamps (W/m²): 34 Arabidopsis tubes (Lux): 10000 Arabidopsis tubes (W/m²): 40 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 2,4 Energy consumption at 37 °C / 75 % RH 1) (W): 600 Noise level approx. (dB (A)): 52 |
BINDER - KBWF 720
[+] View Model SpecificationsDepth | 920 mm (plus 52 mm door handle, I-triangle, connection) |
Height | 1924 mm (incl. casters) |
Width | 1249 mm |
Weight | 374 kg |
Additional Model Specifications | Interior dimensions Width (mm): 970 Height (mm): 1250 Depth (mm): 576 Interior volume (l): 698 Racks (number standard/max.): 3 / 12 Load per rack (kg): 45 Permitted total load (kg): 150 Variable position illumination cassettes: 3 Temperature data (without humidity) Temperature range without illumination cassettes (°C): 0 - 70 Temperature range with illumination cassettes with illumination (°C): 10 - 60 Max. heat compensation up to 40 °C with illumination (W): 1000 Climate data (with humidity) Temperature range without illumination cassettes (°C): 0 - 70 Temperature range with illumination cassettes with illumination (°C): 20 - 60 Temperature variation with illumination (± K): 1,0 - 1,5 Temperature fluctuation with illumination (± K): 0,1 - 0,5 Humidity range without illumination cassettes (% RH): 10 - 80 Humidity range with illumination cassettes, with illumination (% RH): 10 - 75 Humidity fluctuation with illumination (± % RH): = 2,5 Illumination data per light cassette Daylight tubes (Lux): 14200 Daylight tubes (W/m²): 38 Fluora® growth lamps (Lux): 10500 Fluora® growth lamps (W/m²): 31 Arabidopsis tubes (Lux): 14400 Arabidopsis tubes (W/m²): 38 Electrical data IP protection class acc. to EN 60529: IP 20 Voltage (± 10%) 50 / 60 Hz (V): 200-240 1N~ Nominal power at 240 V (kW): 3,5 Energy consumption at 37 °C / 75 % RH 1) (W): 2350 Noise level approx. (dB (A)): 53 |