HORIBA - ULTIMA 2C Series
Manufactured by HORIBA
ULTIMA 2C Series
The ULTIMA 2C provides a complete solution for your laboratory with the speed and flexibility required for many applications where the need for a fast analysis time must not compromise instrument performance. The series offers the features of the ULTIMA 2 with the lowest detection limits using single view radial plasma and unparalleled spectral resolution. To this is added a directly viewed simultaneous optic.
The ULTIMA 2CE is configured for high throughput laboratories following environmental protocols such as US EPA 200.7, which is often the basis for global
environmental methods. The ULTIMA 2CE performs compliant analysis of method 200.7 elements in less than 4 minutes.
The ULTIMA 2C HR is the top-of-the-line in ICP OES instrumentation and offers the performance necessary to achieve accurate results in even the most complex materials, such as zirconium and tungsten, precious metals or applications featuring rare earth elements in trace concentrations.
The ULTIMA 2CE is configured for high throughput laboratories following environmental protocols such as US EPA 200.7, which is often the basis for global
environmental methods. The ULTIMA 2CE performs compliant analysis of method 200.7 elements in less than 4 minutes.
The ULTIMA 2C HR is the top-of-the-line in ICP OES instrumentation and offers the performance necessary to achieve accurate results in even the most complex materials, such as zirconium and tungsten, precious metals or applications featuring rare earth elements in trace concentrations.
Active Questions & AnswersAsk a Question
There are no current Discussions
ICP Systems Service ProvidersView All (15)
Documents & ManualsView All Documents
Features of ULTIMA 2C Series
ULTIMA 2C
Combination of the ULTIMA 2 with 0.5m simultaneous optics.
High performance for a wide range of sample types.
ULTIMA 2CE
Optimized for environmental applications.
US EPA CLP analysis in less than 4 minutes (download reprint).
ULTIMA 2C HR
Combination of the ULTIMA 2 with 1.0m simultaneous optics.
Greater performance in resolution and sensitivity.
Top-of-the-line in ICP OES instrumentation.
Excellent for complex materials such as W, Zr, U, precious metals or rare earth elements in trace concentrations.
Unmatched performance not seen in any other instrument available today.
General Specifications
There are no General Specifications available.
Series Modals
HORIBA - ULTIMA 2C & 2CE
[+] View Model SpecificationsDepth | 990 mm |
Height | 1700 mm |
Width | 2220 mm |
Weight | 550 kg |
Additional Model Specifications |
HORIBA - ULTIMA 2C HR
[+] View Model SpecificationsDepth | 1880 mm |
Height | 1700 mm |
ICP Detection Method | Optical Emission |
Width | 2450 mm |
Weight | 815 kg |
Additional Model Specifications |