Shimadzu - AA-6200

Manufactured by  Shimadzu
Follow this Equipment

Atomic Spectroscopy

Shimadzu's new double beam AA-6200 atomic absorption spectrophotometer recombines high performance and affordability. The double beam system provides the superior baseline stability expected from high performance optical systems at an affordable price. Use of AtomicA's Windows®-based software Wizard function provides easy operation for system control and data processing. The AA-6200 uses the least linear bench space of any atomic absorption spectrophotometer in the world. In spite of its compactness, the performance and capability is superior. In fact, the AA-6200 outperforms other atomic absorption instruments many times its physical size.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Updated byDim

avatar placemark

Asked bygharnum

Need Equipment Support?

Request Support
Features of AA-6200

Easy Operation   Use of WindowsTM software provides easy operation for system control and data processing. The Wizard function guides the user through the entire analytical procedure. Worksheets permit the experienced user direct access to the all the parameter's settings.  

Compactness   Shimadzu AA-6200 uses one of the least linear bench space of any Atomic Absorption Spectrophotometers in the world. In spite of its compactness, the performance has not been compromised. In fact, the AA-6200 outperforms other atomic absorption instruments many times it's physical size.  

Double Beam & D2   The double beam sytem provides superior baseline stability expected from high performance optical systems. The BGC-D2(Deterium Background Correction) Compensates for matrix interferences.

General Specifications
Depth 425 mm
Graphite Furnace0
Height370 mm
Lamps2-Iamps simultaneously lit
Width 690 mm
Power Requirements AC220V, 230V, 50/60Hz
Peak Power300 VA
Optical SystemDouble Beam
Weight38 kg
Wavelength Range190 to 900 nm
Additional Specifications

Monochromator:  
Aberration corrected Czerny-Turner monochromator  
Holographic grating (1,600 lines/mm)  
Slit:  
0.2nm, 0.7nm Manual setting  
Background Correction:  
D2-Lamp method  
Lamp Mode:  
Emission, Non-BGC, BGC-D2  
Frequency:  
100HZ  
Nebulizer:  
Nebulizer integrated impact bead and jacket tip  
Pt/Ir capillary  
Chamber:  
Polypropylene  
Burner:  
Fixed back/forward position and burner height  
(Simple switching of Air/C2H2 and N2O/C2H2 burner)  
Titanium 10cm slot burner (Optional high-temperature burner)  
Gas Control:  
Manual setting of flow rate  
Automatic Air/N2O switching system  
Safety:  
Gas pressure monitoring to prevent flashback  
Automatic flame monitoring  
Safety interlock for misuse of burner  
Automatic flame extinguish when power failure  
Ignition:  
Push ignite button  
Software:  
Software based on MS Windows® 2000/XP  
Ambient temperature:  
Temperature : 10-35°C  
Humidity range:  
Humidity : 45-80% (less than 70% when temperature is greater than 30°C)  
Standard accessories:  
Burner Head of 10cm slot. Nebulizer assembly. Deuterium lamp. Drain tube.  
Teflon tube for sample suction. Hose assembly for Air. Hose assembly for C2H2.  
RS-232C connection cable (9P-9P). AC cable for 220, 230V.