Hitachi Medical Systems - LaChrom Elite® HPLC with 3100 Mass Detector

Manufactured by  Hitachi Medical Systems
Follow this Equipment

Simple, Efficient and Sensitive Detection of Your HPLC Analyte

With the addition of the highly flexible and versatile 3100 Mass Detector, Hitachi’s LaChrom Elite ® HPLC system further solidifies its position as the leader in chromatographic analysis for a wide range of applications.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of LaChrom Elite® HPLC with 3100 Mass Detector
  • Seamless integration of the HPLC system and the 3100 Mass Detector with Empower™ 2 control.    
  • Performs SIR for sensitive and selective quantitation, peak tracking and impurity profiling.    
  • Equipped with dual ESI/APCI source as standard, with optional APPI available.    
  • IntelliStart software mode automates hardware setup and method development.
General Specifications
Scan Speed 10000 amu/sec
Standard Flow Rate 5 to 1000 µL/min
Mass Spectrometer TypeQuadrupole Mass Analyzer
Additional Specifications

3100 Mass Detector Specifications    
IntelliStart™ technology:     

        
  1. System parameter checking and alerts    
  2. Integrated sample/calibrant delivery system and programmable divert valve    
  3. Automated mass calibration    
  4. Automated sample tuning    
  5. Automated SIR method development    
  6. LC/MS System Check—automated on-column performance test    
    
API source:     
        
  1. ZSpray™ dual-orthogonal source for robust sampling    
  2. Vacuum isolation valve    
  3. Tool-free sampling cone removal    
  4. Plug-and-play probes    
  5. De-clustering cone gas    
  6. Software control of all gas flows    
    
Ionization modes:    
        
  1. Electrospray—included as standard    
  2. ESCi multimode ionization—included as standard    
  3. IonSABRE™ APCI—option    
  4. Dual APCI/APPI—option    
    
Mass analyzer: Single quadruple analyzer    
Detector: Dynolite photo multiplier detector    
Acquisition modes:    
1) Full scan MS    
2) Selected ion recording (SIR)    
Scan rate: Up to 10,000 amu/sec in contiuum or centroid modes    
Sensitivity: 1 pg (5 uL injection of 0.2 pg/uL reserpine at 300 uL/min flow rate yields at response > 50:1 S/N (RMS), for both APCI positive ion mode and electrospray positive ion mode.    
Vacuum system: Single, split flow air-cooled Pfeiffer vacuum turbomolecular pump evacuating the source and analyzer    
One Leybold Sogevac SV4OBI rotary backing pump    
Software: System control via Empower™ 2    
Regulartory approvals: IVD, NRTL, and CE