BWB Technologies USA LLC - BWB SUGAR Flame Photometer

Manufactured by  BWB Technologies USA LLC
Follow this Equipment

Redefining Sugar refining from beet or cane.

Redefining Sugar refining from beet or cane.

Features:

  • Uniquely hybridized BWB dual-channel, focused for high accuracy potassium and sodium measurements
  • "IRS" (Internal Reference Standard) available
  • 4-20MA 2 wire output compatible with scada software
  • Live online monitoring
  • Constant condensation stream feeds with the use of the proprietary BWB collection cup
  • Built-in air compressor; Pioneered by BWB technologies in 2007 and proven now with over 1000 units in global field use
  • Solutions and labware included; "Just add gas", the hallmark of the user-friendly BWB Flame Photometeer (FES) program
  • Specialized calibration "Ready to use" solutions supplied at 1, 5, 10 and 20PPM
  • User-selectable decimal places
  • Intuitive user interface for true ease of use
  • Display prompts step by step by step operation
  • Data sharing via PC link with BWB's FP/PC app

In keeping with the Globally accepted published papers from 1977 forward, potassium and sodium detection are now available online 24/7 with a Uniquely configured channel of detection for extreme accuracy along the range of potassium control.

This winning proprietary format has been improved with a unique adaptation and optimization of the proprietary BWB optical array detection systems, which in this iteration of the BWB Specialty Flame Photometers allows for a single channel of precise and accurate potassium and sodium measurement.

This Specialty Flame Photometer has been requested and designed for the global Sugar Production marketplace.

There were a few traditional Flame Photometer manufacturers over the decades who had served this market and now these robust and fantastic units are coming out of service.

Enter the BWB SUGAR Flame Photometer with specialized potassium and sodium channel detection, supplied with hybridized specific needs multiple point calibration solutions for potassium and sodium. Per our customers’ requests, our Collection Cup provides Real-Time sample access for our mixing chamber/detection systems and only requires that the sample is at or near ambient temperature and customer-provided ~5ml/minute feed to our unique “Collection Cup” system.

FP/PC APP

This totally unique BWB feature allows multiple installation details to be shared via intranet or internet links to provide “Distributed Control” via a single Control room with staff completely remote from the Refinery site itself. For large Sugar Companies with multiple sites around the world, this allows Expertise from a centralized location anywhere in the world with real-time virtually limitless data accumulation and analysis.

.csv files allow users to construct novel and proprietary Excel spreadsheets and to share data quickly and efficiently.

Technical Data:

  • Sample rate: 2-3.5ml/min
  • Tubing materials: PTFE and Teflon
  • Required desk space for Instrument: 50cm (H) x 45cm (W) x 45cm (D)*
    • *For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney
  • Instrument size:
    • Syn Fuels Flame Photometer: 51cm (H) x 38cm (W) x 41cm (D) | (20in x 14in x 16in)
    • Shipping: 62cm (H) x 55cm (W) x 47cm (D) | (24in x 22in x 19in)
  • Weight:
    • Syn Fuels Flame Photometer: 15.3kg
    • Shipping: 25kg
  • Optimal range:
    • Single point calibration:
      • Na 0.1 – 60ppm
      • K 0.05 – 100ppm
      • Li 0.05 – 50ppm
      • Ca 1.0 – 100ppm
    • Multi Point Calibration:
      • Na 0.1 – 1000ppm
      • K 0.05 – 1000ppm
      • Li 0.05 – 1000ppm
      • Ca 1.0 – 1000ppm
  • Reproducibility: <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).
  • Specificity:  Na/K/Li = <0.5% to each other when equal in concentration at <100ppm
  • Limit of detection (LOD) and limit of quantification (LOQ) displayed:
    • LOD LOQ
    • Na – 0.03ppm Na – 0.1ppm
    • K – 0.02ppm K – 0.05ppm
    • Li – 0.02ppm Li – 0.05ppm
    • Ca – 0.3ppm Ca – 1ppm
  • Time to stability: Less than 15 seconds after sample is introduced into the flame
  • Ions measured: Simultaneous measurement of Na, K, Li, Ca
  • Interfaces:
    • USB
    • 0-2.5 volt output (based on sample concentration linked to element of users choice)
    • Optional 4-20mA output in place of the above
  • Optional integrated printer .CSV and .PDF generated reports and files via FP-PC software
  • Collection Cup fitted as standard allowing live reading
  • Recommended minimum warm-up time based on ambient temperature: 21°C – 40 minutes
  • Power requirements: 100V – 250V AC at 50 or 60Hz
  • Fuel requirement: Propane, Butane or Natural Gas* (regulated to 19Bar. Flow rate of 0.4l/min)
    • *with modifications. BWB Technologies recommends either Propane or Butane for optimum results.
  • Readout: LCD, four-line, alphanumeric, backlit.
Active Questions & AnswersAsk a Question

There are no current Discussions

Elemental Analyzers Service ProvidersView All (6)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features

There are no Features available.

General Specifications

There are no General Specifications available.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com