BWB Technologies USA LLC - BWB SYN FUELS Flame Photometer

Manufactured by  BWB Technologies USA LLC
Follow this Equipment

Reliable and accurate analysis of all four atoms of interest.

Reliable and accurate analysis of all four atoms of interest.    
   
Features:    
Simultaneous detection and display of all 4 atoms of interest   
"IRS" (Internal Reference Standard) available   
Intuitive user interface for true ease of use    
Display prompts step by step by step operation   
Built-in air compressor    
Solutions and labware included    
Data sharing via PC link   
4 user selectable decimal places    
Optional integrated printer uses readily available paper (added option)    
IQ, OQ, PQ web-based certification available    
Correction of CA for the interference from high levels of NA    
This powerful and growing global industry now has the attending facilities for Synthetic Fuels or Bio-Fuels production. For this derivative product BWB Technologies offers a hybridized Flame Photometer we have named Syn Fuels.   
   
   
The BWB SYN FUELS Flame Photometer is the first and only 4 channel flame photometer with simultaneous detection and display of all 4 elements. A high quality and high performance instrument, the BWB SYN FUELS employs modern technology to improve both accuracy and stability while significantly reducing analysis time.   
   
   
The fluid handling sections of the BWB SYN FUELS Flame Photometer   
incorporate proprietary engineered thermoplastics that are highly chemically resistant to withstand the solvents encountered in Synthetic Fuels production facilities.   
   
   
The majority of our Global clients purchase a BWB Sugar FES for the   
beet or cane refining plant and the Syn Fuels FES for the bio-conversion plant site.    
   
   
For non Sugar processors embracing Syn Fuels, the BWB XP is typically the BWB FES of interest during the bio-conversion processes.   
   
   
Technical Data:    
Sample rate: 2-3.5ml/min   
   
Tubing materials: PTFE and Teflon    
   
Required desk space for Instrument:   
   
50cm (H) x 45cm (W) x 45cm (D)*   
   
For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.   
   
   
Instrument size:    
   
Syn Fuels Flame Photometer   
51cm (H) x 38cm (W) x 41cm (D)   
(20in x 14in x 16in)   
   
   
Shipping:    
62cm (H) x 55cm (W) x 47cm (D)   
(24in x 22in x 19in)   
   
   
Weight:    
   
Syn Fuels Flame Photometer – 15.3kg   
   
Shipping – 25kg   
   
   
Optimal range:    
   
Single point calibration   
   
Na 0.1 – 60ppm    
   
K 0.05 – 100ppm    
   
Li 0.05 – 50ppm    
   
Ca 1.0 – 100ppm    
   
   
Multi Point Calibration   
   
Na 0.1 – 1000ppm    
   
K 0.05 – 1000ppm    
   
Li 0.05 – 1000ppm    
   
Ca 1.0 – 1000ppm   
   
   
Reproducibility:    
   
<1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).    
   
   
Specificity:    
   
Na/K/Li = <0.5% to each other when equal in concentration at <100ppm    
   
Limit of detection (LOD) and   
limit of quantification (LOQ) displayed:    
   
LOD LOQ    
   
Na – 0.03ppm Na – 0.1ppm   
   
K – 0.02ppm K – 0.05ppm   
   
Li – 0.02ppm Li – 0.05ppm   
   
Ca – 0.3ppm Ca – 1ppm   
   
   
Time to stability: Less than 15 seconds after sample is introduced into the flame   
   
Ions measured:    
   
Simultaneous measurement of Na, K, Li, Ca   
   
   
Interfaces:    
   
USB   
   
0-2.5 volt output (based on sample concentration linked to element of users choice)   
   
Optional 4-20mA output in place of the above   
   
Optional integrated printer .CSV and .PDF generated reports and files via FP-PC software   
   
Collection Cup fitted as standard allowing live reading   
   
   
Recommended minimum warm up   
time based on ambient temperature:   
   
21°C – 40 minutes    
   
   
Power requirements:    
   
100V – 250V AC at 50 or 60Hz   
   
   
Fuel requirement:    
   
Propane, Butane or Natural Gas*   
regulated to 19Bar. Flow rate of 0.4l/min   
   
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.    
   
   
Readout:    
   
LCD, four line, alpha numeric, back lit.
Active Questions & AnswersAsk a Question

There are no current Discussions

Elemental Analyzers Service ProvidersView All (6)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features

There are no Features available.

General Specifications

There are no General Specifications available.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com