Thermo Scientific - Orion 350 PerpHecT Advanced

Manufactured by  Thermo Scientific
Follow this Equipment

Orion 350 PerpHecT® Advanced Benchtop pH Meter

Orion 350 PerpHecT meters include all the pH basics plus simultaneous display of pH, mV or RmV (ORP) and temperature. Use autocalibration with built-in Auto-Buffer-Recognition of three buffers or enter custom buffer values. Temperature compensation can be LogRTM, automatic (with an ATC probe) or manual. These enhanced PerpHecT meters come complete with GLPcheck for verification of electrode reliability and GLPdocTM for printouts compatible with "Good Laboratory Practices," ROSS ResolutionTM to 0.001 pH units, and RS232 communications. These meters are available with a premium Orion PerpHecT ROSSTM electrode, or in a GLP package which includes an Orion 8272BN PerpHecT ROSS Sure-Flow® electrode, PRT300 ink-based printer and cable. Three (3) year meter warranty.

This system is ideal for busy, multi-user laboratories or plant environments. pH measurements are easy with the help of advanced features such as autocalibration, LogR mode, automatic temperature compensation, choice of pH resolution and diagnostic operator assistance codes.

(1) Over 20°C temperature calibration range. PerpHecT® LogRTM temperature measurement and compensation specifications are based on the use of PerpHecT and PerpHecT ROSSTM brand electrodes. Use of other brand electrodes may impact performance.
Active Questions & AnswersAsk a Question

There are no current Discussions

pH Meters Service ProvidersView All (13)

Request Support
Features of Orion 350 PerpHecT Advanced
  • Simultaneous Display of pH, mV (ORP) and Temperature
  • GLPcheckTM for Active Electrode Verification
  • Orion 350 includes Basic ISE (Concentration) Capability
General Specifications
mV Resolution0.1 mV
pH Range0 to 14
pH ResolutionSelectable
Temperature Resolution0.1 °C
Temperature Accuracy0.1 °C
mV Accuracy0.2
pH Accuracy0.005
pH Meter Temperature Range0 to 100 °C
pH Meter TypeBenchtop
Additional Specifications

pH slope : 80 to 120%
pH Auto-Buffer-Recognition : 4.01, 7.00, 10.01
pH Calibration Points : 3
Temp. Rel. Accuracy LogR (1) : ±0.5°C
Millivolt LogR Range : ± 1000.0 mV
Millivolt Relative Accuracy : ± 0.2 mV or ± 0.05% of reading, whichever is greater
Display : LED
Inputs : BNC, pin tip ref, ATC, Power
Outputs : RS232, 2.5 mm pin Recorder
Power Requirements : AC Line, 110 V, 220 V or 240 V
Agency Approvals : CE, CSA, UL
Environmental Requirements : 5 to 45°C and 5 to 85% relative humidity, non-condensing

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com