Rigaku - PILATUS 3R series
Manufactured by Rigaku
Rigaku Oxford Diffraction offers the PILATUS3 R 200K as the standard detector for single crystal systems. PILATUS3 R...
Rigaku Oxford Diffraction offers the PILATUS3 R 200K as the standard detector for single crystal systems. PILATUS3 R detectors are true photon counting devices that combine the following features to make them the best commercially available detectors for protein crystallography:
the highest sensitivity
the lowest readout noise
the fastest readout time
the lowest point spread function
fully air-cooled and maintenance free
Whether you’re collecting data for small or weakly diffracting samples or collecting data for S-SAD phasing, a Rigaku Oxford Diffraction system configured with a PILATUS3 R detector ensures the most accurate data collection for your samples. The PILATUS3 R 200K is also ideal for high throughput screening and ligand binding studies, especially when coupled with an ACTOR automatic sample changer.
Why the HPAD detector?
There are basically four types of detectors currently being used with single crystal diffractometers: HPAD, CCD, CMOS, and IP. The HPAD is the newest technology and is unique in that it is a photon counting detector that directly detects X-ray photons without the intermediate step of converting the photons to light with a phosphor.
The HPAD detector allows for shutterless data collection due to the extremely fast readout. This capability eliminates errors in the diffraction data originating from shutter timing and goniometer stop/starts, which are invariably associated with traditional data collection, and minimizes data collection time. In addition, the extremely low noise characteristics means that you can count poorly diffracting samples for a long period of time without swamping the signal with electronic noise. The combination of these features means that you will collect better data faster.
Whether you’re collecting data for small or weakly diffracting samples or collecting data for S-SAD phasing, a Rigaku Oxford Diffraction system configured with a PILATUS3 R detector ensures the most accurate data collection for your samples. The PILATUS3 R 200K is also ideal for high throughput screening and ligand binding studies, especially when coupled with an ACTOR automatic sample changer.
There are basically four types of detectors currently being used with single crystal diffractometers: HPAD, CCD, CMOS, and IP. The HPAD is the newest technology and is unique in that it is a photon counting detector that directly detects X-ray photons without the intermediate step of converting the photons to light with a phosphor.
The HPAD detector allows for shutterless data collection due to the extremely fast readout. This capability eliminates errors in the diffraction data originating from shutter timing and goniometer stop/starts, which are invariably associated with traditional data collection, and minimizes data collection time. In addition, the extremely low noise characteristics means that you can count poorly diffracting samples for a long period of time without swamping the signal with electronic noise. The combination of these features means that you will collect better data faster.
Active Questions & AnswersAsk a Question
There are no current Discussions
X-ray Diffraction Service ProvidersView All (9)
Documents & Manuals
There are no Documents or Manuals available.
Features of PILATUS 3R series
- Direct detection * Excellent point spread function – top hat * Excellent signal-to-noise ratio via single photon counting * Adjustable threshold to suppress fluorescence * High dynamic range: 1,048,576:1 photons per pixel * High counting rates: up to 2x10? photons per second per pixel * Short readout time: 7 ms * Frame rate up to 20 images per second * Electronically gateable * Radiation tolerant design * Other PILATUS3 R format detectors are available: PILATUS3 R 300K, PILATUS3 R 1M
General Specifications
There are no General Specifications available.