BINDER - Series FDL

Manufactured by  BINDER
Follow this Equipment

BINDER safety drying chambers are extremely accurate and ensure that drying is quick and even.

Drying chambers for limited quantities of solvent 
BINDER safety drying chambers are extremely accurate and ensure that drying is quick and even. With the option of operation at temperatures ranging up to 350 °C, these drying chambers can meet different requirements and are suitable for a wide range of applications. In its FDL series, BINDER has developed drying chambers for limited quantities of solvent, which provide the ideal environment for all samples containing solvents. The FDL series includes drying chambers with a highly efficient filter cartridge and symmetrical air flow with defined flow rates. The cartridge can be replaced, guaranteeing high levels of operational safety along with the electronic fresh air monitoring system. The drying chambers operate with absolute temperature accuracy, even with high ventilation, thereby providing the basis for high-quality results and reproducible tests. The patented APT.line™ preheating chamber technology ensures that temperature distribution is homogeneous inside the drying chambers and test conditions are consistent across the entire usable space, regardless of the amount or size of the sample. 
 
Drying chambers with maximum safety levels and ease of handling 
BINDER drying chambers in the FDL series are the combination of maximum operational safety and consistent, reliable test conditions with ease of operation. Heat dissipation is minimal thanks to the chambers' 60-mm-thick insulation and the tight housing door is fitted with a 2-point door closure. The entire chamber interior is made of stainless steel, allowing the usable space to be cleaned thoroughly in no time. This is also helped by the fact that there are no built-in fixtures, as BINDER drying chambers are equipped with two chrome-plated racks instead. The safety drying chambers in the FDL series are the number one choice for samples containing solvents.
Active Questions & AnswersAsk a Question

There are no current Discussions

Lab Ovens Service ProvidersView All (15)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of Series FDL

Important characteristics 

  • Temperature range: room temperature plus 5 °C to 300 °C * APT.line™ preheating chamber technology * Controller with time-segment and real-time programming * 2 chrome-plated racks * Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating * Replaceable filter cartridge, Class M6 * Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm * Computer interface: RS 422
General Specifications

There are no General Specifications available.