Carbolite - Tube Furnace up to 1600°C - STF / TZF
The Carbolite Gero STF single zone and TZF 3-zone high temperature tube furnace range is available at 1500 °C and 1600 °C.
This range of tube furnaces does not include an integral work tube and one must be selected as an additional item. The work tube length is dependent on the application eg for use with modified atmosphere or vacuum.
The TZF 3-zone high temperature tube furnace has heated lengths of 450 and 610 mm. An extended uniform zone in the mid-section of the work tube is achieved with the use of end zone controllers which track the centre zone temperature and compensate for the loss of heat from the tube ends.
Active Questions & AnswersAsk a Question
There are no current Discussions
Lab Furnaces Service ProvidersView All (8)
Documents & Manuals
There are no Documents or Manuals available.
Features of Tube Furnace up to 1600°C - STF / TZF
Standard features
1500°C & 1600°C maximum operating temperatures * Single zone models fitted with Carbolite Gero 301 PID controller with single ramp to setpoint and process timer * 3-zone models fitted with 1 x programmable 3216P1 and 2 x 3216CC end zone controllers, with retransmission of setpoint * Accepts work tubes up to 60 or 90 mm outer diameter depending on model * Heated lengths, single zone 180, 450 or 610 mm (STF) * Heated lengths, 3-zone 450 or 610 mm (TZF) * Silicon carbide heating elements * Horizontal configuration
Options (specify these at time of order) * A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications * Over-temperature protection (recommended to protect valuable contents & for unattended operation) * Alternative mounting options are available * Optionally configured for 2 phase or 3 phase electrical supply (depending on model) * A range of additional work tubes, end seals and work tube packages is available for use with modified atmosphere and/or vacuum * Vacuum packages with a choice of rotary vane pump or turbomolecular pump are available for furnaces with tube inner diameters of 60 mm and above * Wide choice of tube diameters and materials is available: eg quartz, ceramic, metal * Insulation plugs & radiation shields to prevent heat loss & improve uniformity * Control module with 2 meter conduit to furnace (TZF) * Hook and strap work tube support
General Specifications
There are no General Specifications available.
Additional Specifications
STF 15/180
Max temp (°C) 1500
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 60
Dimensions: Heated length (mm) 180
STF 15/450
Max temp (°C) 1500
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 450
STF 15/610
Max temp (°C) 1500
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 610
STF 16/180
Max temp (°C) 1600
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 60
Dimensions: Heated tube length (mm) 180
STF 16/450
Max temp (°C) 1600
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated tube length (mm) 450
STF 16/610
Max temp (°C) 1600
Number of heated zones Single zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated tube length (mm) 610
TZF 15/450
Max temp (°C) 1500
Number of heated zones Three zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 450
TZF 15/610
Max temp (°C) 1500
Number of heated zones Three zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 610
TZF 16/450
Max temp (°C) 1600
Number of heated zones Three zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 450
TZF 16/610
Max temp (°C) 1600
Number of heated zones Three zone
Dimensions: Max outer diameter accessory tube (mm) 90
Dimensions: Heated length (mm) 610