Anton Paar - TAG 4

Manufactured by  Anton Paar
Follow this Equipment

The automatic Tag closed-cup tester measures the flash point, the lowest temperature at which the vapors of a sample ignite upon the application of..

The automatic Tag closed-cup tester measures the flash point, the lowest temperature at which the vapors of a sample ignite upon the application of an ignition source.

The tester can also be used to detect the ability of a sample to yield flammable vapors when maintained at an equilibrium temperature by the flash/no flash method.

TAG 4 is suitable for flash point applications of jet fuels, solvents, chemicals, etc.

Active Questions & AnswersAsk a Question

There are no current Discussions

Gas and Air Analyzers Service ProvidersView All (10)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of TAG 4

Benefits at a Glance

  • Two cooling systems with Peltier elements are available: an economical air-cooled model and a low-temperature version with external water cooling
  • The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary
  • The patented One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, igniter and detector contacts
  • An extended measuring range up to 110 °C enables you to go beyond the conventional scope of the method

Convenient Operation

  • Test initiation by pre-installed standard test methods and ability to customize methods by user-defined programs
  • Outside flame sensors increase the system’s safety, especially for work with samples that have no conventional flash point but burn outside the test cup (e.g. due to flame-inhibiting components)
  • Splashproof touch-key panel with large LCD
  • A multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth

Customized User Flexibility

  • PC-software FPPNet (optional) for convenient remote handling and test data storage
  • Insulation hood (optional) to protect the cover and shutter assembly from icing during low-temperature flash point tests
  • Draft deflector (optional) recommended for gas ignition tests
  • Calibration set (optional)
  • Small-volume sample cup (optional)
General Specifications
Depth 470 mm
Height470 mm
Width 230 mm
Power Requirements 115 V/230 V, 50 Hz/60 Hz, 180 W (air-cooled) 230 V, 50 Hz/60 Hz or 115 V, 60 Hz, 150 W (liquid-cooled)
Weight8 kg
Additional Specifications

Application range(°C/°F selectable)  
10 °C to 110 °C (air-cooled) 
-30 °C to 110 °C (liquid-cooled) 
 
Ignition  
Gas and electric (interchangeable) 
 
Heating  
According to method or user-defined 
 
Cooling of Peltier elements  
Air-cooled (by built-in fan) 
Liquid-cooled (with tap water or circulation cooler) 
 
Flash detection  
Thermocouple 
 
Barometric pressure correction 
Automatic correction 
 
Safety  
Overheat protection, automatic shut-off 
 
Interfaces  
2x RS232 
 
Gas supply  
50 mbar of propane or butane