Malvern Panalytical - Kinexus
Manufactured by Malvern Panalytical
Kinexus Rotational Rheometer
Kinexus is a unique rheometer designed for tomorrow's rheology needs across all industries and application areas. Designed from the ground up, the Kinexus rheology platform is the result of more than four years intensive product development. Kinexus enables you to precisely analyze the rheology, or flow and deformation properties of your materials
Active Questions & AnswersAsk a Question
1Replies
Problems with Newtonian linear fit
Recent Questions & Answers
Rheometers Service ProvidersView All (5)
Documents & Manuals
There are no Documents or Manuals available.
Features of Kinexus
Kinexus enables you to precisely analyze the rheology, or flow and deformation properties of your materials:
- from liquids to solids.
- from processability to product performance.
- from temperature to time dependence.
- from simple viscosity to complex viscoelastic parameters.
General Specifications
There are no General Specifications available.
Series Modals
Malvern Panalytical - Kinexus lab+
[+] View Model SpecificationsDepth | 485 mm |
Height | 680 mm |
Width | 490 mm |
Weight | 47 kg |
Additional Model Specifications | Torque range - viscometry 0.05µNm to 200mNm (continuous) Torque range - oscillation 0.05µNm to 200mNm (continuous) Torque resolution 0.1nNm Position resolution<10nrad Angular velocity range 10nrad/s to 500rad/s Step change in strain <10ms Frequency range 6.28µrad/s to 942rad/s (1µHz to 150Hz) Motor inertia 13 µN.m.s Normal force range 0.001N to 20N (50N optional) Normal force response time <10ms Vertical lift speed 0.1 µm/s to 35mm/s Vertical lift range (measurable) 230mm Gap resolution (over full range) 0.1 µm Fully configurable vertical profiles By speed and normal force Raw instrument variables 5kHz constant streaming data Complete sample history Data available from loading to unloading USB2 instrument interface Plug & play Quick connect geometries Plug & play; auto-configuration Cartridge environmental controllers Plug & play; auto-configuration Plate environmental controller -40 to 200 ° C (0.01 ° C resolution) Interchangeable lower plates Varying diameters & surface finishes Cylinder environmental controller -30 to 200 ° C (0.01 ° C resolution) Open frame and open base design Maximum space for accessory integration |
Malvern Panalytical - Kinexus pro+
[+] View Model SpecificationsDepth | 485 mm |
Height | 680 mm |
Width | 490 mm |
Power Requirements | 110 V |
Weight | 47 kg |
Additional Model Specifications | Standard operating modes: Direct strain control. Shear rate control. Shear stress control. Torque range (Viscometry - Controlled Rate and Controlled Stress): 10nNm to 200mNm. Torque range (Oscillation - Controlled Strain and Controlled Stress): 2nNm to 200mNm. Torque resolution: 0.1nNm. Position resolution: <10nrad. Angular velocity range: 10nrads-1 to 500rads-1 Step change in strain: <10ms. Frequency range: 6.28µrads-1 to 942rads-1 (1µHz to 150Hz). Motor inertia: 13µN.m.s2. Normal Force range: 0.001N to 20N (50N optional). Normal Force resolution: 0.5mN. Normal Force response time: <10ms. Vertical lift speed: 0.1µms-1 to 35mms-1 Vertical lift range (measurable): 230mm. Gap resolution (over full vertical lift range): 0.1µm Fully configurable vertical profiles: By speed and by Normal Force. Raw instrument variables: 5kHz constant streaming data. Complete sample history: Data available from loading to unloading as standard. Instrument interface: USB2 – plug and play. Temperature control range: -40°C to 200°C (Peltier plate and active hood cartridges). -30°C to 200°C (Peltier cylinder cartridge) Temperature resolution: 0.01°C. |
Malvern Panalytical - Kinexus ultra+
[+] View Model SpecificationsDepth | 485 mm |
Height | 680 mm |
Width | 490 mm |
Power Requirements | 110 V |
Weight | 47 kg |
Additional Model Specifications | Standard operating modes: Direct strain control. Shear rate control. Shear stress control. Torque range (Viscometry - Controlled Rate and Controlled Stress): 5nNm to 250mNm. Torque range (Oscillation - Controlled Strain and Controlled Stress): 0.5nNm to 250mNm. Torque resolution: 0.05nNm. Position resolution: <10nrad. Angular velocity range: 10nrads-1 to 500rads-1. Step change in strain: <10ms. Frequency range: 6.28µrads-1 to 942rads-1 (1µHz to 150Hz). Motor inertia: 13µN.m.s2. Normal Force range: 0.001N to 20N (50N optional.) Normal Force resolution: 0.5mN Normal Force response time: <10ms. Vertical lift speed: 0.1µms-1 to 35mms-1. Vertical lift range (measurable): 230mm. Gap resolution (over full vertical lift range): 0.1µm Fully configurable vertical profiles: By speed and by Normal Force. Raw instrument variables: 5kHz constant streaming data. Complete sample history: Data available from loading to unloading as standard. Instrument interface: USB2 – plug and play. Quick-connect geometries: Auto-identification and auto-configuration – plug and play. Interchangeable lower plates: Varying pedestal diameters and surface finishes. Cartridge environmental controllers: Auto-identification and auto-configuration – plug and play. Temperature control range: -40°C to 200°C (Peltier plate and active hood cartridges). -30°C to 200°C (Peltier cylinder cartridge). Temperature resolution: 0.01°C. |