HORIBA - Ultima™ Extreme
Manufactured by HORIBA
The fully integrated supercontinuum white light laser-powered lifetime fluorometer.
The fully integrated supercontinuum white light laser-powered lifetime fluorometer.
In the Ultima Extreme, we seamlessly combine our fluorometer with the high intensity and broad wavelength range of a supercontinuum laser.
What is a supercontinuum laser, also known as a white light laser? It is a bright source that, unlike other lasers, light over a broad spectral range, from just above 400 nm to over 2 µm. Because of this range and pulse width characteristics, in the range of 10s of picoseconds or longer, it makes an excellent source option for TCSPC measurements.
In the Ultima Extreme, we seamlessly combine our fluorometer with the high intensity and broad wavelength range of a supercontinuum laser.
What is a supercontinuum laser, also known as a white light laser? It is a bright source that, unlike other lasers, light over a broad spectral range, from just above 400 nm to over 2 µm. Because of this range and pulse width characteristics, in the range of 10s of picoseconds or longer, it makes an excellent source option for TCSPC measurements.
Active Questions & AnswersAsk a Question
There are no current Discussions
Fluorescence Detector Service ProvidersView All (21)
Documents & Manuals
There are no Documents or Manuals available.
Features of Ultima™ Extreme
- Select any excitation wavelength from 400nm to over 2 µm for lifetime measurements with the 300-1200nm excitation monochromator or filters. Wavelengths below 430 nm can still be addressed using our existing DeltaDiodes, or optional doubler. * Select pulsing frequency from 100 kHz – 20 MHz (using required pulse picker) * Complete optical, mechanical and software integration: * Adapter for use with excitation monochromator * Complete delay and signaling integration for synchronization * Control of wavelength, and pulse frequency directly from DataStation Software, in addition to monitoring the laser power. * Large sample compartment (compatible with cryostats) * Cell holder with facility for recirculating liquid temperature control * Motorized excitation optics with UV-grade fused silica lenses, filter and mount for polarizer: a wide choice of interchangeable laser diode and LED-based excitation sources are available as accessories Motorized emission optics with UV-grade fused silica lenses, filter and mount for polarizer Emission monochromator: TDM-1200 Seya-Namioka type, featuring motorized wavelength drive (300 nm to 1200 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized adjustable slits (1 nm to 32 nm) * Emission monochromator: TDM-800 Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized adjustable slits (1 nm to 32 nm) * R3809-50 MCP-PMT detector in cooled housing (interlocked with lid of sample compartment) with close-coupled CFD-2G-A picosecond timing amplifier/discriminator and Fluoro3PS ultra-stable HV detector power supply. * FluoroHub A+ timing electronics - measures picoseconds to seconds (depending on excitation source) * All cables and interconnections * System supplied on a 37 x 70 cm baseplate
General Specifications
There are no General Specifications available.