The world’s only CCD-based benchtop spectrofluorometer with a built-in UV-VIS...

The world’s only CCD-based benchtop spectrofluorometer with a built-in UV-VIS spectrophotometer. 
 
HORIBA Scientific combined the world’s only CCD based benchtop spectrofluorometer with a UV-VIS spectrophotometer and created the Dual-FL. 
 
The Dual-FL features spectral rates as fast as 80,000 nm/s, and a water Raman S/N sensitivity greater than 20,000:1 RMS. 
 
Collect incredibly rapid kinetics data, or complete excitation emission matrix (EEMs) in seconds. 
 
And, it also has a built-in UV-VIS spectrophotometer. Use it as your lab UV-VIS, or collect simultaneous dual-mode fluorescence and absorbance data to correct inner-filter effects in your spectra.
Active Questions & AnswersAsk a Question

There are no current Discussions

Fluorescence Detector Service ProvidersView All (21)

Request Support
Features of Dual-FL

The world’s only CCD-based benchtop spectrofluorometer with a built-in UV-VIS spectrophotometer.   

HORIBA Scientific combined the world’s only CCD based benchtop spectrofluorometer with a UV-VIS spectrophotometer and created the Dual-FL.   

The Dual-FL features spectral rates as fast as 80,000 nm/s, and a water Raman S/N sensitivity greater than 20,000:1 RMS.   

Collect incredibly rapid kinetics data, or complete excitation emission matrix (EEMs) in seconds.   

And, it also has a built-in UV-VIS spectrophotometer. Use it as your lab UV-VIS, or collect simultaneous dual-mode fluorescence and absorbance data to correct inner-filter effects in your spectra.

General Specifications

There are no General Specifications available.

Additional Specifications

Hardware   

  • The only true simultaneous absorbance-fluorescence system available   
  • TE-cooled CCD fluorescence emission detector for rapid data acquisition up to 100 times faster than any other benchtop fluorometer   
  • Corrected UV-VIS absorbance detection path for stability and accuracy   
  • Double grating excitation monochromator for superior stray light rejection   
  • Matching bandpass for absorbance and fluorescence spectra   
  • Automatic sample changer option (two or four position)   
  • Compatible with flow cells and titrator   
       
    Software   
       
  • Optimized experiment set-up menus minimize user confi guration time   
  • Complete NIST-traceable corrected fluorescence spectra automatcally generated   
  • Spectral and kinetic analysis tools for both absorbance and fluorescence data   
  • Methods and batch protocols for automating multiple sample measurement