We set a new standard in capillary electrophoresis with the 8-capillary 3500 and 24-capillary 3500xL Genetic Analyzers....
We set a new standard in capillary electrophoresis with the 8-capillary 3500 and 24-capillary 3500xL Genetic Analyzers.
The 3500 8-capillary platform can run a wide variety of applications —including de novo sequencing and resequencing (mutational profiling)—as well as microsatellite analysis, MLPA™, LOH, MLST, AFLP® and SNP validation or screening. The majority of applications can be run on a single polymer and capillary array. The 3500 Series Data Collection Software integrates seamlessly with several downstream software packages to provide comprehensive analysis of genetic data.
The 3500 8-capillary platform can run a wide variety of applications —including de novo sequencing and resequencing (mutational profiling)—as well as microsatellite analysis, MLPA™, LOH, MLST, AFLP® and SNP validation or screening. The majority of applications can be run on a single polymer and capillary array. The 3500 Series Data Collection Software integrates seamlessly with several downstream software packages to provide comprehensive analysis of genetic data.
Active Questions & AnswersAsk a Question
There are no current Discussions
DNA Sequence Analyzers Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of ABI 3500 Series Genetic Analyzer
- 8 capillary system that can easily be upgraded to a 24-capillary system when you’re ready * New single-line 505 nm, solid-state long-life laser—utilizes a standard power supply; requires no heat-removal ducting * Powerful, integrated data collection and primary analysis software provides real-time assessment of data quality * Radio Frequency Identification (RFID) technology tracks key consumables data and records administrative information * Advanced multiplexing capabilities for DNA fragment analysis with up to six unique dyes * Unrivaled application flexibility—one array and one polymer are used for most applications * Simple setup, operation and maintenance—the easiest-to-run, easiest-to-own DNA sequencer to date
General Specifications
Depth | 61 cm |
Height | 72 cm |
Temperature Range | 15 to 30 °C |
Width | 61 cm |
Detection Method | CCD Camera detector |
Power Requirements | 100-240V, 50-60Hz |
Peak Power | 471 VA |
Optical System | solid-state laser, single-line 505nm |
Weight | 82 kg |
Electropheresis Type | Capillary |