Shimadzu - PPSQ-51A/53A
Greater Simplicity and Reliability in the Determination of Amino Acid Sequences Software Compliant with FDA 21 CFR Part 11
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of PPSQ-51A/53A
Analytical Stability and Higher Detection Baseline Stability PPSQ series protein sequencers separate PTH-amino acids isocratically. This improves baseline stability and allows high-sensitivity analysis of PTH-amino acids.
Retention Time Reproducibility Isocratic sequence analysis provides more stable retention times. Therefore, peaks detected in previous cycles can be cancelled using substation chromatogram processing, making it easier to identify sequences.
Simple, Easy-to-Use Data Analysis Functions Specialized protein sequencer software makes it simple to perform the reprocessing of chromatograms, the overlay of multiple chromatograms, and the automatic estimation of amino acid sequences, which are required for sequence analysis.
- Reprocessing of chromatograms required for data analysis
- Overlay of multiple chromatograms
- Automatic estimation of amino acid sequences
Compliance with FDA 21 CFR Part 11 LabSolutions PPSQ software provides compliance with FDA 21 CFR Part 11 guidelines and enables compliance with the security, user management, and audit trail requirements specified by FDA 21 CFR Part 11.
Security Users are managed on the basis of groups, with each user being recognized by means of a username and password. Unique groups can be created by including persons having different access privileges. Clearly defining each user’s access privileges prevents unauthorized changes to settings, instrument operation, and data access.
User Management LabSolutions’ user administration comprises the setting of rights groups and assignment of rights to users just as in Windows. Access rights required for each user can be set by assigning various levels of access to each user. This helps achieve effective user administration and more efficient laboratory operations.
Audit Trail Logins and logouts to the system, changes in users and groups, and the start and completion of acquisition, together with the username and the time, are all recorded. The recorded operational log can be registered in the database to provide traceability.
Software Validation The integrity of the programs that comprise the system and the raw data acquired by instruments can be checked, ensuring the reliability of the system and data. The results of these alteration checks can be managed as printouts.
General Specifications
There are no General Specifications available.
Series Modals
Shimadzu - PPSQ-51A
[+] View Model SpecificationsDepth | 500 mm |
Height | 540 mm |
Width | 510 mm |
Weight | 43 kg |
Additional Model Specifications | Reaction method Edman degradation Reaction time 46.5 min/cycle Number of reactors 1 Sample immobilization method Glass fiber disk (8 mm dia.) or PVDF membrane Reactor temperature control range 10 °C above room temperature to 60 °C Converter temperature control range 10 °C above room temperature to 70 °C Number of reagents/solvents 7 Reagent/solvent delivery method Nitrogen gas pressure |
Shimadzu - PPSQ-53A
[+] View Model SpecificationsDepth | 500 mm |
Height | 540 mm |
Width | 510 mm |
Weight | 45 kg |
Additional Model Specifications | Reaction method Edman degradation Reaction time 48 min/cycle Number of reactors 3 Sample immobilization method Glass fiber disk (8 mm dia.) or PVDF membrane Reactor temperature control range 10 °C above room temperature to 60 °C Converter temperature control range 10 °C above room temperature to 70 °C Number of reagents/solvents 7 Reagent/solvent delivery method Nitrogen gas pressure |