Thermo Scientific - SOLA II Sulfur Online Analyzer
Measure total sulfur in liquid hydrocarbon fuel process streams with the Thermo Scientific™ SOLA II Sulfur Online...
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byMassimoA
Lab Ovens Service ProvidersView All (15)
Documents & ManualsView All Documents
- Continuous Flare Stack Emission Monitoring Using the SOLA II Flare System App Note
- Increasing the Lifetime of the Pyrolyzer Heater in SOLA II Systems
- Replacing a Watlow Series 93 Temperature Controller with a Watlow EZ-ZONE PM6 Series Controller
- SOLA II – Trace Sulfur Analysis in the Production of Biofuels
- Sola II Sulfur Online Analyzer data sheet
- Spare Parts List for the SOLA II And SOLA II Trace Sulfur Online Analyzer
- The SOLA II Trace in Reforming and Isomerization
- Using Watlow Series 93 Temperature Controller in SOLA II System
Features of SOLA II Sulfur Online Analyzer
Key Features:
Full scale measurement range are from 0 to 5 ppm/wt to 0 to 9000 ppm/wt detection limits as low as 0.25 ppm * Automatic stream switching is also available for dual-stream or quad-stream applications * Sample combustion uses air only, no pure oxygen is required * Longer life and better low detectable limits than non-pulsed UV systems * Low consumables * Low maintenance * Continuous sample injection * Easy operation * Low sulfur in fuels measurement needs met now and in the future
Analog Outputs: * 4-20mÅ DC for each stream (optional) * Alarm Outputs - One Global Dry Contact Triggered by One or More of the Following: * Low sample flow alarm (optional) * Low detector flow alarm * Oven/Pyrolyzer temperature fault * Injection valve fault * Purge failure * Calibration fault * Detector temperature fault * Detector lamp voltage fault * One out of service dry contact triggered by: analyzer in calibration or suspension of analyzer
Analog Inputs: * Optional 4-20mÅ DC inputs from density meter for automatic density compensation of ppm S (w/w) * Optional 4-20mÅ DC input from sample flowmeter * Digital Data Communications: * Dual channel with the following optional configurations: * RS-232 Modbus & RS-485 Modbus * Dual channel RS-485 Modbus * TCP/IP encapsulated Modbus & RS-485 Modbus
SOLA II Modbus Remote Interface: * Complete remote control of SOLA * Automatic logging of analysis results and analyzer parameters * Communication to SOLA II via serial or TCP/IP encapsulated Modbus enables remote diagnostics via modem
SOLA Web Remote Interface: * Complete remote control of SOLA * Ability to download 24 hours of analysis results and analyzer parameters * Communication to SOLA II via local area network (TCP/IP) enables remote diagnostics via modem
Local MMI (Man Machine Interface): * Status of all analyzer parameters (e.g., furnace & oven temperatures, PMT and lamp voltage, detector flow rate, etc.) and analytical results available on front mounted displays * Push button menu access * Hazardous area classification remains intact while operating local display
Recommended for: * Diesel * Gasoline * Kerosene * Jet Fuel * Naptha * Natural Gas * Refinery Fuel Gas * LPGs
General Specifications
There are no General Specifications available.