Gilson - Automated GX-271 GPC Clean-up System
Maximize your automated sample prep clean-up prior to GC, GC/MS, HPLC, and LC/MS analysis.
Automate post-extraction clean-up of interfering substances from environmental samples, food products, and animal tissue by Gel Permeation Chromatography (GPC) prior to analysis by GC, GC/MS, HPLC, or LC/MS. Failure to remove these interfering compounds can cause poor analytical results, shorten column life, and increase analytical downtime.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of Automated GX-271 GPC Clean-up System
- The system features a Direct Injection Module and a fraction collection valve located on the Z-arm, increasing efficiency by reducing sample carryover and post valve dead volume. * The Automated GPC system is controlled with TRILUTION® LC Software, a user-friendly, easy-to-use, flexible program that was specifically designed to meet the laboratory needs. The software features pre-programmed methods specific to GPC post-extraction clean-up processes. * Gilson GPC Clean-up Systems meet clean-up guidelines set forth by the USEPA, USFDA, USDA, USGS, ISO, CFIA, AOAC International and European Union (EN 1528, EN 12393, S19) requirements.
General Specifications
There are no General Specifications available.
Additional Specifications
Pump:
Reciprocating pump with single-piston interchangeable head, constant stroke and fast refill motion, internal pulse dampener and pressure feedback
Accuracy:
< ± 1%
Repeatability:
< 1%
Flow Rate:
10 uL/min to 10 mL/min
Dimensions (w x d x h):
33 x 33 x 15 cm (13 x 13 x 6 in)
Maximum Pressure:
4000 psi (276 bar)
Injection Volume:
GX-271 Liquid Handler/Injector: 20 uL to 5 mL (5 mL standard)
Vertical Punch Strength:
3.2 kg (7 lb) for septum piercing
Syringe Pump:
402 Single Syringe Pump with 10 mL syringe
Sample Rack Capacity Options:
13 x 100 mm tubes, 16 x 100 mm tubes and other options available upon request
Collection Rack Capacity Options:
25 x 200 mm tubes, 38 x 200 mm tubes, 125 mL or 250 mL Boston Round Bottles, Caliper TurboVap™ Evaporation Tubes (50 and 200 mL, Labconco RapidVap Evaporation Vessels (100 mL flat, 450 mL flat or with stem), 125 mL and 250 mL flasks for rotary evaporation and other options available upon request.
UV Detector:
Wavelengths at 254nm or 280 nm with 40 uL Flow Cell (10 mm path length)
Software Control:
Computer control via Ethernet communication and TRILUTION® LC Software
GPC Clean-up Columns:
Compatible with various GPC Clean-up columns from low pressure glass to high pressure stainless steel
Optional GPC System Organizer Dimensions (w x d x h):
39.2 x 37.9 x 93.7 cm (15.5 x 14.9 x 36.9 in)
Environmental Conditions:
For indoor use only
Altitude: 2000 m
Temperature: 5ºC - 40ºC
Air pressure: 75 - 105 kPa
Pollution degree: 1 or 2, in accordance with IEC 66
Humidity: Maximum relative humidity 80% for temperatures up to 31º C, decreasing linearly to 50% relative humidity at 40ºC
Manufacturing Standards:
Meets applicable safety and EMC certification standards; UL and CE certified
Fuse:
5 x 20 mm “T” type 2.50A
One for 100 - 120V; two for 220 - 240V
Power Requirement:
Frequency: 50 - 60 Hz
Voltage: 100 - 240V (universal input)
Current rating: 2.0A for 100 - 120V or 1.0A for 220 - 240V
Dimensions (w x d x h):
59.7 x 54.1 x 57.1 cm (23.5 x 21.3 x 22.5 in)