Shimadzu - DSC-60 Plus Series
Excellent Sensitivity with Fast Cooling
Active Questions & AnswersAsk a Question
Calibration
Recent Questions & Answers
Updated bym ezzat
Need Equipment Support?
Documents & ManualsView All Documents
Features of DSC-60 Plus Series
High-Sensitivity Measurements with a Wide Calorimetric Measurement Range
The noise level, less than 0.5 µW when held at 150°C, enables measurement of the smallest calorimetric changes. The large dynamic calorimetric measurement range of ±150 mW means materials with very large calorimetric changes can be characterized.
Automated Measurement Improves Efficiency
With the same footprint as the standard model, the DSC-60A Plus model has a compact, built-in autosampler which enables automated measurement, analysis, and report printout for up to 24 samples, improving the efficiency of product development and quality control activities.
Sub-Ambient Measurements Using Standard Cooling Chamber
The cooling chamber installed as standard on the DSC-60 Plus calorimeters permits measurement down to -140°C using liquid nitrogen. The sample loading temperature function enables quick sample exchange during sequential analysis without moisture condensation. For consecutive and cycled sub-ambient measurements, DSC-60 Plus models with auto-cooling systems are available.
PC Controlled TA-60WS Thermal Analysis Workstation
The TA-60WS thermal analysis workstation is the interface between the DSC-60 Plus series and PC. It includes easy-to-use data acquisition, data analysis, and reporting software. In addition, up to four Shimadzu thermal analysis instruments of any type can be controlled simultaneously by each TA-60WS.
Compliant with Analytical Laboratory Regulations Including US FDA 21 CFR Part 11
Software accompanying the TA-60WS thermal analysis workstation is available to comply with guidelines such as PIC/S GMP and electronic record and electronic signature (ER/ES) regulations, including US FDA 21 CFR Part 11.
Sample Pans for a Wide Range of Applications
To complement the DSC-60 Plus series, a wide range of sample pans, including ones composed of Aluminum, Platinum, Alumina, Nickel, Copper, and Quartz and hermetically sealed and pressure-proof pans, are available.
General Specifications
Depth | 500 mm |
DSC Type | Heat Flux DSC |
Height | 500 mm |
Width | 320 mm |
Power Requirements | AC100V, 120V, 230V 50/60Hz MAX 800VA * 2 |
Weight | 28 kg |
Additional Specifications
Measurement principle:
Heat-flux type
Temperature range:
-140 to 600°C *1(With standard cooling chamber and using liquid nitrogen)
Calorimetric measurement range:
±150mW
Noise level:
Less than 0.5ΜW (rms, when held at 150°C?
Sample quantity (pan quantity):
Standard AL crimp pan approx.40Μl
Programmable heating/cooling rate:
+/- 0.1 to +/- 99.9°C /min ( 0.1°C /hr or 0.1°C /min step)
Programmable hold time:
1min - 999hr (1min or 1hr step)
Atmosphere:
Nitrogen, inert gas, dry air gas flow
Interface:
RS-232C, 1
Control software:
Thermal analysis workstation TA-60WS