Thermo Scientific - ARL ADVANT’X IntelliPower Series
Manufactured by Thermo Scientific
Sequential X-Ray Fluorescence Spectrometers
Advances in X-ray fluorescence analysis
The ARL ADVANT’X family of X-ray fluorescence (XRF) sequential spectrometers with IntelliPower technology provides the choice of performance and value to suit your true requirements. These high tech instruments allow analysis of up to 84 elements of the periodic table in conductive or non-conductive solids or liquids. Many application areas will find their perfect match within this new family of instruments, notably:
Monitoring of trace elements in oils or polymers
Analysis of major and minor elements in cement and quarry materials full analysis
of glasses, metals, ores, refractories and geological materials
Easy sample preparation
Speed of analysis
High stability
Good precision
Wide dynamic range (from ppm levels to 100%)
Simple and rapid analysis of totally unknown samples thanks to state-ofthe-art standard-less analysis packages, i.e. QuantAS™, UniQuant® and OptiQuant™
Thanks to a clever management of power, the ARL ADVANT’X IntelliPower spectrometers can operate at 1200W and even 2500W without requiring external water cooling. Therefore neither tap water, nor a water cooler is required in these cases. At higher power levels (3.6 kW or 4.2 kW), energy savings and reduced stress on the X-ray tube are obtained
thanks to intelligent management of the X-ray tube power.
The ARL ADVANT’X family of X-ray fluorescence (XRF) sequential spectrometers with IntelliPower technology provides the choice of performance and value to suit your true requirements. These high tech instruments allow analysis of up to 84 elements of the periodic table in conductive or non-conductive solids or liquids. Many application areas will find their perfect match within this new family of instruments, notably:
of glasses, metals, ores, refractories and geological materials
Thanks to a clever management of power, the ARL ADVANT’X IntelliPower spectrometers can operate at 1200W and even 2500W without requiring external water cooling. Therefore neither tap water, nor a water cooler is required in these cases. At higher power levels (3.6 kW or 4.2 kW), energy savings and reduced stress on the X-ray tube are obtained
thanks to intelligent management of the X-ray tube power.
Active Questions & AnswersAsk a Question
1Replies
ARL Advant XP
Need Equipment Support?
Documents & ManualsView All Documents
Features of ARL ADVANT’X IntelliPower Series
- OXSAS allows performing rapid high quality analyses with templates leading through the analysis operation * Simple definition and comprehensive operation of sample batches. With support of priority samples. Makes unattended analyses handy * Integrated Analytical Assistant guides the creation or extension of methods with best analytical parameters for rapid and accurate analyses * Fast calibration with multiple analyte curve display, instant base curve calculation, templates for edition and measurement of calibration standards. Calibration curve determination using multi-variable regression with a range of correction models and integrated theoretical alphas calculation * Optional standard-less analysis packages: UniQuant, OptiQuant and the semiquantitative QuantAS offer additional analysis versatility * Flexible display of scans with graphical investigation tools * Multi-purpose analysis display with wideranging optional data. e.g. the analysis calculation steps help the validation of methods * Numerous customizable on-line processing functions, with manual or automatic application * Comprehensive post-treatment of results, including export * Real on-line integrated SPC * SCT Manager: Status and history of Setting-up samples, Control samples and Type standards give the overview of the analytical capability of the instrument and of each method any time. * Easy to use: one click creation of a batch with all samples requiring analysis * Effective monitoring and maintenance tools maximize the system uptime * Very comprehensive contextual Help including "How-To" guides * Integrated Microsoft® SQL Server Desktop Engine relational database which stores your set up and analyses data
General Specifications
There are no General Specifications available.
Series Modals
Thermo Scientific - ARL ADVANT’X IntelliPower 1200
[+] View Model SpecificationsDepth | 83 cm + 43 cm |
Height | 94 cm + 31 cm |
Width | 109 cm + 20 cm |
Power Requirements | 3.1 kVA single phase |
Weight | 460 kg |
Additional Model Specifications | Element range Boron (Nr. 5) to transuranics (> Nr. 92) providing all necessary crystals are fitted on a universal goniometer. Fluorine (Nr. 9) to transuranics (> Nr. 92) with SmartGonio. X-ray generator Solid state 1200 W high frequency generator of maximum voltage 60 kV and maximum current 60 mA. All kV/mA combinations must be chosen to be less than 1200 W Max. line voltage variation: -15% to +10%. Stability: ± 0.0001% per 1% variation Sample loading Basic: 1 position. Optional: 12 cassette or large capacity X-Y magazine (see general specifications) Cooling system Closed circuit for deionised water flowing through liquid/air heat exchanger. Flow is regulated between 0.5 and 5 lt/min according to generator setting (to keep X-ray tube temperature constant) |
Thermo Scientific - ARL ADVANT’X IntelliPower 2500
[+] View Model SpecificationsDepth | 83 cm + 83.5 cm |
Height | 94 cm + 47 cm |
Width | 109 cm + 41 cm |
Power Requirements | 4.9 kVA single phase |
Weight | 460 kg |
Additional Model Specifications | Element range Boron (Nr. 5) to transuranics (> Nr. 92) providing all necessary crystals are fitted on a universal goniometer. Fluorine (Nr. 9) to transuranics (> Nr. 92) with SmartGonio. X-ray generator Solid state 2500 W high frequency generator of maximum voltage 60 kV and maximum current 100 mA. All kV/mA combinations must be chosen to be less than 2500 W. Max. line voltage variation: -15% to +10%. Stability: ± 0.0001% per 1% variation Sample loading Basic: 1 position. Optional: 12 cassettes or large capacity X-Y magazine Cooling system Closed circuit for deionised water flowing through liquid/air heat exchanger. Flow is regulated between 0.5 and 5 lt/min according to generator setting (to keep X-ray tube temperature constant) |
Thermo Scientific - ARL ADVANT’X IntelliPower 3600
[+] View Model SpecificationsDepth | 83 cm |
Height | 94 cm |
Width | 109 cm |
Power Requirements | 6 kVA single phase |
Weight | 450 kg |
Additional Model Specifications | Element range Beryllium (Nr. 4) to transuranics (>Nr. 92) providing all necessary crystals are fitted. Fluorine (Nr. 9) to transuranics (>Nr. 92) with SmartGonio. X-ray generator Solid state 3.6 kW high frequency generator of maximum voltage 60 kV and maximum current 120 mA. Optional generator with maximum settings of 70 kV and 120mA. All kV/mA combinations must be chosen to be less than 3.6 kW. Max. line voltage variation: -15% to +10%. Stability: ± 0.0001% per 1% variation. Sample loading 12 cassette or large capatiy X-Y magazine (see general specifications) Cooling system Built-in closed circuit for deionised water flowing through liquid/liquid heat exchanger. External water needed: T < 20°C, pressure ³ 2 bar. Flow is regulated between 0.5 and 5 lt/min according to generator setting (to minimize water consumption). |
Thermo Scientific - ARL ADVANT’X IntelliPower 4200
[+] View Model SpecificationsDepth | 83 cm |
Height | 94 cm |
Width | 109 cm |
Power Requirements | 7 kVA single phase |
Weight | 450 kg |
Additional Model Specifications | Element range Beryllium (Nr. 4) to transuranics (>Nr. 92) providing all necessary crystals are fitted. Fluorine (Nr. 9) to transuranics (>Nr. 92) with SmartGonio X-ray generator Solid state 4.2 kW high frequency generator of maximum voltage 60 kV and maximum current 120 mA. Optional top performance generator with maximum settings of 70 kV and 140 mA. All kV/mA combinations must be chosen to be less than 4.2 kW. Max. line voltage variation: -15% to +10%. Stability: ± 0.0001% per 1% variation. Sample loading 12 cassette or large capatiy X-Y magazine (see general specifications) Cooling system Built-in closed circuit for deionised water flowing through liquid/liquid heat exchanger. External water needed: T < 20°C, pressure ³ 2 bar. Flow is regulated between 0.5 and 5 lt/min according to generator setting (to minimize water consumption). |