Thermo Scientific - GlycanPac AXR-1
Manufactured by Thermo Scientific
Exceptional Glycan Selectivity with Industry-Leading Resolution> Ultra-high resolution and se...
Exceptional Glycan Selectivity with Industry-Leading Resolution
Ultra-high resolution and selectivity of glycans are attributed to the GlycanPac AXR-1 column's innovative mixed-mode surface chemistry, which combines:
WAX functionality for retention of negatively charged glycans, with separation in order of increasing charge
Reversed-phase functionality for same-charge glycans, with separation according to isomerism and size
Reliable Column Performance
This high-purity spherical silica column is designed and tested for HPLC and UHPLC methods using either fluorescence or MS detection applications. The GlycanPac AXR-1 column uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.
Available in Multiple Formats
Use 1.9Μm columns for UHPLC applications and 3Μm columns for HPLC applications
Select from a variety of dimensions to support the resolution, throughput, or instrumental requirements required for your application
Ultra-high resolution and selectivity of glycans are attributed to the GlycanPac AXR-1 column's innovative mixed-mode surface chemistry, which combines:
This high-purity spherical silica column is designed and tested for HPLC and UHPLC methods using either fluorescence or MS detection applications. The GlycanPac AXR-1 column uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.
Available in Multiple Formats
Active Questions & AnswersAsk a Question
There are no current Discussions
HPLC Columns Service ProvidersView All (22)
Documents & Manuals
There are no Documents or Manuals available.
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
Thermo Scientific - 1.9Μm Particle Size, 2.1 I.D.
[+] View Model SpecificationsParticle Size | 1.9 µm |
Height | 150 mm |
pH Range | 2 to 8 |
Pore Size | 175 Å |
Additional Model Specifications | Column Chemistry WAX and RP Mixed Mode Diameter 2.1 I.D. Flow Rate Recommend 0.2–0.4mL/min; Maximum 0.5mL/min Max. Pressure 10,000 psi Particle Shape Spherical, high purity, porous Temperature <60°C Solvents Compatible with 0–100% aqueous and common HPLC solvents Surface Area 220m2/g |
Thermo Scientific - 1.9Μm Particle Size, 2.1 I.D.
[+] View Model SpecificationsParticle Size | 1.9 µm |
Height | 250 mm |
pH Range | 2 to 8 |
Pore Size | 175 Å |
Additional Model Specifications | Column Chemistry WAX and RP Mixed Mode Diameter 2.1 I.D. Flow Rate Recommend 0.2–0.4mL/min; Maximum 0.5mL/min Max. Pressure 15,000 psi Particle Shape Spherical, high purity, porous Temperature <60°C Pore Size 175Å pH 2.0–8.0 Solvents Compatible with 0–100% aqueous and common HPLC solvents Surface Area 220m2/g |
Thermo Scientific - 3Μm Particle Size, 2.1 I.D. ×
[+] View Model SpecificationsParticle Size | 3 µm |
Height | 150 mm |
pH Range | 2 to 8 |
Pore Size | 175 Å |
Additional Model Specifications | Column Chemistry WAX and RP Mixed Mode Diameter 2.1 I.D. Flow Rate Recommend 0.2–0.3mL/min; Maximum 0.4mL/min Max. Pressure 6,000 psi Particle Shape Spherical, high purity, porous Temperature <60°C Pore Size 175Å pH 2.0–8.0 Solvents Compatible with 0–100% aqueous and common HPLC solvents |
Thermo Scientific - 3Μm Particle Size, 3.0 I.D. ×
[+] View Model SpecificationsParticle Size | 3 µm |
Height | 150 mm |
pH Range | 2 to 8 |
Pore Size | 175 Å |
Additional Model Specifications | Column Chemistry WAX and RP Mixed Mode Diameter 3.0 I.D. Flow Rate Recommend 0.4–0.6mL/min; Maximum 0.75mL/min Max. Pressure 6,000 psi Particle Shape Spherical, high purity, porous Temperature <60°C Solvents Compatible with 0–100% aqueous and common HPLC solvents |
Thermo Scientific - 3Μm Particle Size, 4.6 I.D. ×
[+] View Model SpecificationsParticle Size | 3 µm |
Height | 150 mm |
pH Range | 2 to 8 |
Pore Size | 175 mm |
Additional Model Specifications | Column Chemistry WAX and RP Mixed Mode Diameter 4.6 I.D. Flow Rate Recommend 0.8–1.2mL/min; Maximum 1.5mL/min Max. Pressure 6,000 psi Particle Shape Spherical, high purity, porous Temperature <60°C Solvents Compatible with 0–100% aqueous and common HPLC solvents Surface Area 220m2/g |