Thermo Scientific - GlycanPac AXR-1

Manufactured by  Thermo Scientific
Follow this Equipment

The Thermo Scientific™ GlycanPac™ AXR-1 column is a high-performance, silica-based HPLC column for the...

The Thermo Scientific™ GlycanPac™ AXR-1 column is a high-performance, silica-based HPLC column for the simultaneous separation of glycans by charge, isomerism, and size. It is designed to provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using either fluorescence and/or mass spectrometry (MS) detection.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Features of GlycanPac AXR-1
  • Unique glycan selectivity based on charge, branch/linkage isomerism, and size       * Exceptional resolution for either native or derivatized glycans       * Utility for both high-resolution glycan structural characterization and glycan quantification       * Compatibility with both MS and fluorescence detection methods       * Reliable column performance       * Available in HPLC (3 µm) and UHPLC (1.9 µm) formats.Unique glycan selectivity based on charge, branch/linkage isomerism, and size       * Exceptional resolution for either native or derivatized glycans       * Utility for both high-resolution glycan structural characterization and glycan quantification       * Compatibility with both MS and fluorescence detection methods       * Reliable column performance       * Available in HPLC (3 µm) and UHPLC (1.9 µm) formats.
General Specifications
Particle Size3 µm
Pore Size175 A
Additional Specifications

Column Dimensions        
1.9 Μm: 2.1 × 250mm, 2.1 × 150mm       
3 Μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mm       
       
Particle Size        
Spherical 1.9 Μm, 3 Μm particles       
Substrate        
High-purity, Porous, Spherical Silica       
Surface Area        
220 m2/g       
Pore size        
175 Å       
Functional Group        
WAX and RP Mixed-Mode       
Recommended Flow Rate Range:        
1.9 Μm: 0.2 to 0.4 mL/min. for: all 2.1 mm columns       
3 Μm: 0.8 to 1.2 ml/min for 4.6 × 150 mm       
0.3 to 0.6 ml/min for 3.0 × 150 mm       
0.1 to 0.3 ml/min. for 2.1 × 150 mm       
Pressure Limit        
1.9 Μm: 10,000 psi for 2.1 ×150mm       
15,000 psi for 2.1 × 250mm       
3 Μm: 6,000 psi for all 3 Μm columns       
Temperature Range:        
Ambient to < 60 ºC       
pH Range        
2.0 - 8.0

NewsView All Articles

Looking for

Thermo Scientific - GlycanPac AXR-1?

Shop on LabX.com