Beckman Coulter - DelsaMax Series
The new DelsaMax™ Series offers incredible speed, precision and reliability, allowing for an unprecedented advancement in your nanoparticle research.
The new DelsaMax™ Series offers incredible speed, precision and reliability, allowing for an unprecedented advancement in your nanoparticle research. Each instrument helps you get more insight out of even the smallest samples, faster than ever.
Simultaneous analysis of particles in less than one second.
That’s why the DelsaMax Series is the perfect addition to an already robust family of sophisticated Particle Characterization solutions from Beckman Coulter—reaching all the way back to more than 50 years ago, when Wallace Coulter created the very method that established the field. Proof that we always have, and always will be committed to what’s most important: improving and accelerating your process.
Active Questions & AnswersAsk a Question
There are no current Discussions
Particle Size Analyzers Service ProvidersView All (2)
Documents & Manuals
There are no Documents or Manuals available.
Features of DelsaMax Series
Rapid sizing and zeta potential analysis
Independent measurement systems allow parallel assessment of size and zeta potential in as little as one second, as well as instant result cross-checking.
Lowest sample volumes available
Dynamic light scattering measurement from 0.4 nm to 10,000 nm, at sample volumes as low as 1 ΜL.
More detection, less run time
An unprecedented 32 detectors work simultaneously to make testing faster and increase accuracy.
Sample integrity protection
Fast, sensitive measurements ensure accurate zeta potential without risk of sample degradation.
Intuitive software
Edit data points or “flyers” without re-running samples. Easily overlay results to check for consistency and accuracy.
Optimal setup and distribution
Proprietary normalization algorithm provides robust distributions. Optimized auto-correlation function selects the particles of interest
General Specifications
There are no General Specifications available.
Series Modals
Beckman Coulter - DelsaMax CORE
[+] View Model SpecificationsSample Volume Range | 1.25 to 4 μL |
Measurement Time | 1 sec |
Additional Model Specifications | Dynamic Light Scattering Size Range (Diameter–nm) 0.4 to 5,000 Static Scattering Molecular Weight Range: 300 to 106 Da (concentration dependent) Minimum Sensitivity: 0.1 mg/ΜL Lysozyme Scattering Angle: 90° Minimum Sample Volume: 1.25 Μl standard cuvette, 4 Μl disposable cuvette Correlator: 512 channels (100 nsec sampling time in a multi-tau layout) Data Acquisition Time: 1 to 3,600 seconds |
Beckman Coulter - DelsaMax PRO
[+] View Model SpecificationsMeasurement Time | 1 sec |
Additional Model Specifications | Size Range: 0.4 to 10,000 nm, hydrodynamic diameter (limited by particle sedimentation) Molar Mass Range: 5×107 g/mol (Da) dependent on molecular shape model) |