Shimadzu - MDGC/GCMS-2010

Manufactured by  Shimadzu
Follow this Equipment

Gas Chromatographs

The MDGC/GCMS-2010 is a MDGC system which gives you a excellent separation performance and high reproducibility with the multi-deans switching technology, and supports analyses of complex matrixes like petroleum products, aromas, and optical isomers, with intuitive operation, and ease of maintenance.
Active Questions & AnswersAsk a Question

There are no current Discussions

GC-Single Quad/MSD Service ProvidersView All (1)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of MDGC/GCMS-2010

Multi-Dimensional GC/GCMS System       A multi-dimensional GC/GCMS system performs separation using two columns that have different characteristics. The system has a mechanism in which the components that are insufficiently separated in the first column they pass through (the "1st column") are introduced ("heart-cut") to a second, different column (the "2nd column"). This enables analysis with a level of separation that cannot be attained in conventional single-column analysis.      

Outstanding retention time stability       Multi-Deans Switching       In the past, samples have been introduced to columns using the switching mechanism known as Deans-switching. However, this system results in such problems as a reduced recovery rate and fluctuations in the retention time.       The MDGC/GCMS-2010 system incorporates multi-Deans switching, a new mechanism that significantly reduces the likelihood of fluctuations in the retention times of eluted components, even if switching is performed several times.       

A Wide Variety of Optional Systems       In addition to GCMS, various other detectors, such as an FID or FPD, can be used with the MDGC/GCMS-2010. For example, a headspace sampler and thermal desorption system can be connected and controlled as a pretreatment system. When not using the MDGC/GCMS-2010 as an MDGC system, it is possible to use the GC and GCMS components as independent systems by changing the column and detector connections.      

The switching element is secured to the front of the GC oven at the top, making it easy to replace columns and change connections to detectors and pretreatment systems. Also, stainless steel ferrules with high heat resistance are used for the column connections, so the additional tightening required with conventional Vespel ferrules is not necessary, and burning does not occur.