Chemyx - Fusion Touch
Manufactured by Chemyx
Precision laboratory fluid delivery with wide flow ranges and high delivery accuracy.
Precision laboratory fluid delivery with wide flow ranges and high delivery accuracy.
Set any parameter through a familiar "windows" like environment and change settings from syringe ID, flow rate, volume, and delay time. Syringe dimensions can also be loaded from an internal syringe library stored on the pump. Dual entry modes allow users to wear gloves and still operate the system.
high-precision fluid dosing
Set any parameter through a familiar "windows" like environment and change settings from syringe ID, flow rate, volume, and delay time. Syringe dimensions can also be loaded from an internal syringe library stored on the pump. Dual entry modes allow users to wear gloves and still operate the system.
high-precision fluid dosing
Active Questions & AnswersAsk a Question
There are no current Discussions
Lab Pumps Service ProvidersView All (3)
Documents & Manuals
There are no Documents or Manuals available.
Features of Fusion Touch
- high-precision fluid dosing * wide flow ranges * syringe manufacturer independent * constant and variable flow * USB, RS232, TTL for PC control
General Specifications
There are no General Specifications available.
Series Modals
Chemyx - Fusion 100
[+] View Model SpecificationsDepth | 165 mm |
Height | 114 mm |
Width | 241 mm |
Weight | 3 kg |
Additional Model Specifications | Mode Infuse Only Accuracy ± < 0.35% Reproducibility ± < 0.05% Syringe Size (Min/Max) 0.5µL to 60mL Syringe Flow Rates See Syringe Library for Min & Max Flow Rates Minimum Flow Rate 0.001 ΜL/min (with 0.5ΜL syringe) Maximum Flow Rate 102 mL/min (with 60mL syringe) Linear Force 35lb (15.9kg) Display4.3 inch LCD Touch Screen ConnectivityUSB-B, RS232 and TTL Ports System Dimensions 9.5 x 6.8 x 4.4 inches (24 x 17 x 11 cm) Power 110/220 VAC Motor Drive0.9? Stepper Motor with Micro-stepping Step Resolution 0.098 µm/step Operating Temperature 4°C to 40°C (40°F to 104°F) Storage Temperature-10°C to 70°C (14°F to 158°F) Humidity 20% to 80% RH, non-condensing Classification Class 1 Installation Category II Regulatory ComplianceCE, RoHS, REACH, FCC, IC |
Chemyx - Fusion 200
[+] View Model SpecificationsDepth | 6.5 in |
Height | 4.5 in |
Width | 9.5 in |
Weight | 3 kg |
Additional Model Specifications | Mode Infuse/Withdraw Accuracy ± < 0.35% Reproducibility ± < 0.05% Syringe Size (Min/Max) 0.5µL to 60mL Syringe Flow Rates See Syringe Library for Min & Max Flow Rates Minimum Flow Rate 0.001 ΜL/min (with 0.5ΜL syringe) Maximum Flow Rate 102 mL/min (with 60mL syringe) Linear Force 50lb (23kg) Display 4.3 inch LCD Touch Screen Connectivity USB-B, RS232 and TTL Ports System Dimensions9.5 x 6.8 x 4.7 inches (24 x 17 x 12 cm) Power 110/220 VAC Motor Drive0.9? Stepper Motor with Micro-stepping Step Resolution 0.046 µm/step Operating Temperature 4°C to 40°C (40°F to 104°F) Storage Temperature -10°C to 70°C (14°F to 158°F) Humidity 20% to 80% RH, non-condensing Classification Class 1 Installation Category II Regulatory ComplianceCE, RoHS, REACH, FCC, IC |
Chemyx - Fusion 400
[+] View Model SpecificationsDepth | 6.5 in |
Height | 4.5 in |
Width | 9.5 in |
Weight | 3 kg |
Additional Model Specifications | Infusion-only with high volumetric accuracy for microfluidics and microdialysis use. Flow Rate: Minimum (0.5 Μl syringe): 2 pl/min Maximum (10 ml syringe): 10 ml/min Linear Force: 50 lbs with variable force selection Step Resolution: 0.016 microns |