Anton Paar - DMA 35
Manufactured by Anton Paar
The DMA 35 portable density meter measures the density and concentration of your sample and is characterized by the highest level of user friendliness
The DMA 35 portable density meter measures the density and concentration of your sample and is characterized by the highest level of user friendliness. Its robust and lightweight design enables the use in numerous fields of application and its on-site operation in a wide range of work environments. This basic model enables the manual selection of measuring methods and sample IDs as well as wireless data exchange with a printer or PC. Therefore DMA 35 is an economic solution for general industrial and laboratory applications with constant or only occasionally changing measurement settings.
Active Questions & AnswersAsk a Question
Need Equipment Support?
Documents & ManualsView All Documents
Features of DMA 35
User friendliness
- Compact, lightweight design enabling one-hand measurement
- Easy operation, even when wearing protective gloves
- No-hassle measurement of hard-to-reach samples
- Large LC display with backlight for clear visibility of measuring results
- Measuring cell with inspection window and backlight
Robustness
- Rugged, leakproof housing design
- Designed for industrial and field applications
- Proven resistance of wetted parts against common samples
Wireless communication
- IrDA interface for data exchange with a PC and data export to a printer
Efficiency
- Storage of up to 100 sample IDs for easy sample identification
- Storage of up to 20 measuring methods
- Storage of up to 1024 measurement results including time stamp and sample ID
- Up to five programmable custom functions
- Two exchangeable 1.5 V AA batteries ensure long-term, reliable service
- Energy-saving mode for reduced power consumption provided
- Easy and fast replacement of the entire pump assembly
General Specifications
There are no General Specifications available.
Series Modals
Anton Paar - DMA 35
[+] View Model SpecificationsDepth | 140 mm |
Height | 27 mm |
Width | 138 mm |
Maximum Temperature | 40 °C |
Power Requirements | Two 1.5 V alkaline batteries |
Maximum Viscosity | 1000 mPa.s |
Weight | 345 g |
Sample Size | 2 mL |
Additional Model Specifications | Measuring range: Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 °C to 40 °C (32 °F to 104 °F)* Viscosity: 0 mPa·s to 1000 mPa·s Accuracy: Density: 0.001 g/cm³ ** Temperature: 0.2 °C (0.4 °F) Repeatability, s.d.: Density: 0.0005 g/cm³ Temperature: 0.1 °C (0.2 °F) Supported measuring units: Specific gravity Alcohol tables Sugar/extract tables API functions H2SO4 tables Ten programmable custom functions Data memory: 1024 measured results Interfaces: IrDA OBEX/LPT Intrinsically safe: no Industries: Beverages Chemical Industry Cosmetics, Personal Care Education, Research Electronics Environmental Food Industry Pharmacy, Medicine, Biotechnology |
Anton Paar - DMA 35 Ex
[+] View Model SpecificationsDepth | 140 mm |
Height | 27 mm |
Width | 138 mm |
Maximum Temperature | 40 °C |
Maximum Viscosity | 1000 mPa.s |
Weight | 351 g |
Additional Model Specifications | Measuring range: Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 °C to 40 °C (32 °F to 104 °F) Viscosity: 0 mPa·s to 1000 mPa·s Accuracy: Density: 0.001 g/cm³ ** Temperature: 0.2 °C (0.4 °F) Repeatability, s.d.: Density: 0.0005 g/cm³ Temperature: 0.1 °C (0.2 °F) Supported measuring units: Specific gravity Alcohol tables Sugar/extract tables API functions H2SO4 tables Ten programmable custom functions Data memory: 1024 measured results Interfaces: IrDA OBEX/LPT, RFID Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4 Industries: Chemical Industry Electronics |
Anton Paar - DMA 35 Ex Petrol
[+] View Model SpecificationsDepth | 140 mm |
Height | 27 mm |
Width | 138 mm |
Maximum Viscosity | 1000 mPa.s |
Weight | 396 g |
Additional Model Specifications | Measuring range: Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 °C to 40 °C (32 °F to 104 °F) Viscosity: 0 mPa·s to 1000 mPa·s Accuracy: Density: 0.001 g/cm³ ** Temperature: 0.2 °C (0.4 °F) Repeatability, s.d.: Density: 0.0005 g/cm³ Temperature: 0.1 °C (0.2 °F) Supported measuring units: Specific gravity Alcohol tables Sugar/extract tables API functions H2SO4 tables Ten programmable custom functions Data memory: 1024 measured results Interfaces: IrDA OBEX/LPT, RFID Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4 Industries: Petroleum Industry |
Anton Paar - DMA 35 Tag&Log
[+] View Model SpecificationsDepth | 140 mm |
Height | 27 mm |
Width | 138 mm |
Maximum Temperature | 40 °C |
Maximum Viscosity | 1000 mPa.s |
Weight | 351 g |
Additional Model Specifications | Measuring range: Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 °C to 40 °C (32 °F to 104 °F) Viscosity: 0 mPa·s to 1000 mPa·s Accuracy: Density: 0.001 g/cm³ ** Temperature: 0.2 °C (0.4 °F) Repeatability, s.d.: Density: 0.0005 g/cm³ Temperature: 0.1 °C (0.2 °F) Supported measuring units: Specific gravity Alcohol tables Sugar/extract tables API functions H2SO4 tables Ten programmable custom functions Data memory: 1024 measured results Interfaces: IrDA OBEX/LPT, RFID Intrinsically safe: no Industries: Beverages Chemical Industry Cosmetics, Personal Care Education, Research Electronics Environmental Food Industry Pharmacy, Medicine, Biotechnology |
Videos
DMA 35 portable density meter