PHCBi - MCO-5ACL/MCO-5ACLUV
Manufactured by PHCBi
CytoGROW Compact Incubators
Panasonic CytoGROW Compact Series CO2 incubators offer precise CO2 and O2 control in a compact, space saving design allowing up to three models to be stacked, making them ideal for in vitro simulation of an in vivo environment in a laboratory environment. When arrayed in triple stackable configurations, this unit meets GLP requirements by helping to avoid patient-to-patient cross contamination in individualized patient-specific clinical incubation applications.
Active Questions & AnswersAsk a Question
There are no current Discussions
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of MCO-5ACL/MCO-5ACLUV
- Compact and Stackable
- Active Background Control with InCu-saFe®
- SafeCell UV Protection (Optional)
- Direct Heat and Air Jacket System
- Integrated Microprocessor Control
General Specifications
There are no General Specifications available.
Series Modals
PHCBi - MCO-5ACL
[+] View Model SpecificationsDepth | 28 in |
Height | 35.4 in |
Internal Depth | 20.6 in |
Internal Height | 26.2 in |
Width | 24.4 in |
Internal Width | 19.3 in |
Chamber Volume | 49 L |
Weight | 49 kg |
Shelf Dimensions | 12.2 |
Additional Model Specifications | OUTER DOOR Painted Steel INSULATION Rigid-polyurethane foamed-in place UV LAMP Optional TEMPERATURE CONTROL RANGE Ambient temperature +º5C to 50ºC (ambient temperature: 5ºC to 35ºC) TEMPERATURE UNIFORMITY ±0.25ºC (ambient temperature: 25ºC, setting: 37ºC, CO2: 5 %, no load) MAXIMUM POWER CONSUMPTION Max 205 W CO2 CONTROL RANGE 0% to 20% CO2 CONTROLLER PID Control System CO2 GAS CONNECTION 4 mm to 6 mm (0.157 inch to 0.36 inch) diameter tube can be connected CO2 GAS PRESSURE 0.03 MPa(G) (0.3kgf/cm2(G),4.3 psi(G)) CO2 VARIATION ±0.15% (ambient temperature: 25ºC, setting: 37ºC, CO2: 5%; no load) CO2 SENSOR TYPE TC Sensor DECONTAMINATION METHODS 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) CONTAMINATION CONTROLS Standard 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) and Copper Alloy Interior Surface (inCu-saFe) DISPLAY Digital Touchpad HEATING SYSTEM Direct heat and air jacket HUMIDIFYING SYSTEM Natural evaporation with humidifying pan, 95 %R.H.±5 %R.H. INTERIOR SURFACES Stainless steel containing copper |
PHCBi - MCO-5ACUVL
[+] View Model SpecificationsDepth | 21.6 in |
Height | 22.4 in |
Internal Depth | 14.9 in |
Internal Height | 14.8 in |
Width | 18.9 in |
Internal Width | 13.8 in |
Chamber Volume | 49 L |
Weight | 49 kg |
Shelf Dimensions | 12.2" x 12.2" (310 x 310 mm) |
Additional Model Specifications | OUTER DOOR Painted Steel ACCESS PORT Inner Diameter: 30 mm (1.18 inch), on the back side INSULATION Rigid-polyurethane foamed-in place AIRFLOW Optional AIR FILTER 0.3Μm, Efficiency; 99.97% or more UV LAMP Optional TEMPERATURE CONTROL RANGE Ambient temperature +º5C to 50ºC (ambient temperature: 5ºC to 35ºC) TEMPERATURE UNIFORMITY ±0.25ºC (ambient temperature: 25ºC, setting: 37ºC, CO2: 5 %, no load) MAXIMUM POWER CONSUMPTION Max 205 W CO2 CONTROL RANGE 0% to 20% CO2 CONTROLLER PID Control System CO2 GAS CONNECTION 4 mm to 6 mm (0.157 inch to 0.36 inch) diameter tube can be connected CO2 GAS PRESSURE 0.03 MPa(G) (0.3kgf/cm2(G),4.3 psi(G)) CO2 VARIATION ±0.15% (ambient temperature: 25ºC, setting: 37ºC, CO2: 5%; no load) CO2 SENSOR TYPE TC Sensor DECONTAMINATION METHODS 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) CONTAMINATION CONTROLS Standard 24 hr full chamber UV decontamination (SafeCell Ultraviolet Light) and Copper Alloy Interior Surface (InCu-saFe®) DECONTAMINATION CYCLE TIME UV DISPLAY Digital Touchpad HUMIDIFYING SYSTEM Natural evaporation with humidifying pan, 95% R.H.±5 %R.H. INTERIOR SURFACES Stainless steel containing copper |