NuAire - In-VitroCell ES NU-5830 Direct Heat CO2 Incubator
Manufactured by NuAire
NuAire Direct Heat CO2 Incubators provide a stable in-vivo growth model with heating elements located on all 6 sides of the chamber.
The In-VitroCell ES NU-5830 Hypoxic Microbiological CO2 Incubator controls oxygen levels within the growth chamber through displacement with nitrogen aiding in carcinogenic tumour and/or aging research. In-VitroCell offers 145°C high heat sterilization and a 95°C humidified decontamination cycles as a preventative measure and to eradicate contamination in the growth chamber. On screen instructions read users through the process.
Active Questions & AnswersAsk a Question
There are no current Discussions
CO2 Incubator Service ProvidersView All (28)
Documents & Manuals
There are no Documents or Manuals available.
Features of In-VitroCell ES NU-5830 Direct Heat CO2 Incubator
- Temperature and Gas Monitor and Control
- Status Indicators – Screen Identity; Run or Standby mode; Door Adjar; Air and CO2 Inject; Air and CO2 Chamber Sampling
- Date and Time Functions in International Format
- Password Protection
- Onscreen Icon Descriptions – Pressing on any icon will provide a description of what the item is.
- Onscreen Directions – Directions are available to perform calibrations.
- Step-by-Step directions (i.e. sterilization cycle procedure)
- Alarm Status Menu - A red “Alarm Status” text button will appear on the Main Screen to indicate a fault within the Incubator system.
- Maintenance Required Reminders – Onscreen Icon “MAINTENACE REQUIRED” appears when a programmable reminder (0 to 48 months) hits set point to notify filter check.
- Historical Performance Monitor – Temperature and CO2 gas history is available to view onscreen in graphical form or can be downloaded via USB for alarms, control systems, events, and performance information.
- Service Settings and Complete Diagnostic Controls
- System Information
- Display Settings
- Available in English, French, German, and Spanish
General Specifications
CO2 Incubator Type | Direct Heat |
Depth | 27 in |
Temperature Uniformity | 37 °C |
Height | 40 in |
Width | 26.5 in |
Peak Power | 625 W |
Chamber Volume | 200 L |
CO2 Sensor | Infrared (IR) |
Idle Power | 250 W |
CO2 Range | 0.1 to 20 % |
O2 Range | 2 to 21 % |
Shipping Weight | 235 lbs |
Maximum Shelf Load | 20 lbs |
O2 Accuracy | 1 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 19.75 x 18.75 |
Temperature Accuracy | 0.1 °C |
Incubator Orientation | Benchtop |