New Brunswick Scientific - Innova 40 Series
Manufactured by New Brunswick Scientific
Benchtop Incubator Shakers with Refrigeration Option
For precise control of temperature and speed, Innova 40 & 40R incubator shakers have no equal. These versatile lab workhorses provide "set it and forget it" programming, automatically changing operating conditions on your pre-programmed command. Innova laboratory shakers culture a wide variety of cell types, and with high-temperature capability can perform a variety of molecular biology techniques.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Shakers Service ProvidersView All (14)
Documents & ManualsView All Documents
Features of Innova 40 Series
User-Friendly
- Ready When You Are. Automatically ramp temperature up, so your study can get started when you arrive in the lab. Speed up, slow down or stop agitation on a timed basis. Or let your shaker place your cultures in metabolic stasis until you're ready to attend to them. It's all possible with our easy-to-use programmable controller
- Controls for Entering & Viewing Setpoints are Exceptionally Easy-to-Use. Display is clearly visible from all angles, across the room, and in the dark
- Output Signal to RS232 Enables Data Logging and Computer Control
- Timed Studies Can Be Programmed for Automatic Agitation Shut-Off. End-of-study alarm & status light can be deactivated for continuous operation
- Audible and Visible Alarms alert the user to setpoint deviations. Audible alarm can be muted
- Electronics & Mechanical Components Are Enclosed, Protected From Accidental Spills
- Modular Refrigeration System in Innova 40 lets you easily add refrigeration option at any time, even in the field
- Automatic Restart After Power Interrupt with Non-Volatile Memory keeps studies running smoothly
- NBS Shakers Are the Quietest-Running In the Industry providing a more favorable work environment
- A Wide Variety of Interchangeable Accessory Platforms are available to accommodate gel trays, culture tubes and flasks. Platforms from previous NBS model shakers can be used
- Easy Opening Lids. Hydraulic arms on Innova 40 make it easy to raise and keep the lid open
- Intelligent Design Provides Convenient Access to all electronic and heating/cooling components to simplify maintenance
Culture-Friendly
- Microprocessor Controls With Self-Correcting PI Feedback precisely regulate speed, running time, and incubation, as well as optional refrigeration
- Uniform and Precise Temperature Control: ±0.1°C with uniformity of ±0.25°C at 37°C
- Expanded Temperature Range Eliminates Need to Order a More Expensive High-Temperature Model. Innova 40: 5°C above ambient to 80°C Innova 40R: 15°C below ambient to 80°C ( Minimum temperature 4°C)
- Speed Range: 25 - 500 rpm (±1 rpm) Provides Versatility for Culturing a Wide Range of Cell Types
- Unique Acceleration - Deceleration Circuit prevents sudden starts and stops. Minimizes mechanical damage for longer shaker life. Eliminates flask closure wetting which would otherwise interfere with oxygen transfer
Safe & Durable
- NBS' Often Imitated, But Never Duplicated Triple-Eccentric Drive is precisely counterbalanced to impart smooth, uniform motion to all flasks regardless of their position on the platform. Ensures dependable day-in and day-out performance
- Open-Lid Cutout Switch stops agitation when chamber is open
- Thermostat Fail-Safe shuts off heaters if high limit is exceeded
- Cool-Running Brushless Motor never requires lubrication; and provides years of long life
- cETLus Certified. Meets CSA, UL and CE standards
- Comprehensive Warranty - Covers three-years on parts and two years on labor
General Specifications
There are no General Specifications available.
Additional Specifications
Glassware capacity: up to (64) 50mL, (34) 125mL, (25) 250mL, (16) 500mL, (9) 1L, (5) 2L, and (4) 3 L flasks.
Platform Size: 18
Series Modals
New Brunswick Scientific - 40
[+] View Model SpecificationsDepth | 30 in |
Height | 24 in |
Internal Depth | 21.5 in |
Plate Depth | 18 in |
Internal Height | 14 in |
Maximum Shaking Speed | 500 rpm |
Plate Width | 18 in |
Width | 22 in |
Internal Width | 20.25 in |
Maximum Temperature | 80 °C |
Power Requirements | 120V 60Hz; 230V 50Hz; 100V 60Hz; 100V 50Hz, 800 VA |
Weight | 138 lbs |
Controls | Digital |
Motor | Triple-eccentric counterbalanced drive in cast iron housing with 9 permanently lubricated ball bearings. Driven by solid-state brushless DC motor |
Shaking Speed | 25 to 500 rpm with 3/4 |
Shaker Type | Incubating Shaker |
Additional Model Specifications | Temperature accuracy and control: ± 0.1°C at 37°C with a nominal uniformity of ± 0.25°C Refrigeration: Innova 40R only. Hermetically-sealed compressor uses CFC-free refrigerant Heaters: Low watt-density, resistance heaters with high-temperature safety thermostat cut-out Timer and Parameter Control: 4 modes: - Speed and temperature continuous - Shaker can be set to run from 0.1 to 99.9 hours - On-board firmware can program multiple parameter changes to temperature and speed - Shaker control and data logging via RS-232 and remote computer running conventional laboratory management software or HyperTerminal Alarms, Audible and Visible: Indicate when speed deviates more than 5 rpm or temperature more than 1°C from setpoint, and when program or time has finished. Alarm may be muted Safety, Mechanical and Electronic: Acceleration circuit prevents sudden starts and stops. Sensor shuts off temperature when high-temperature limit is exceeded Setpoint Retention: Setpoints and operating status retained by non-volatile memory. Automatic restart after power is restored (indicated by flashing display). |
New Brunswick Scientific - 40R
[+] View Model SpecificationsDepth | 30 in |
Height | 24 in |
Internal Depth | 21.5 in |
Plate Depth | 18 in |
Internal Height | 14 in |
Maximum Shaking Speed | 500 rpm |
Plate Width | 18 in |
Width | 22 in |
Internal Width | 20.25 in |
Maximum Temperature | 80 °C |
Power Requirements | 120V 60Hz; 230V 50Hz; 100V 60Hz; 100V 50Hz, 1,500 VA |
Orbital Diameter | 1 in |
Weight | 184 lbs |
Controls | Digital |
Motor | Triple-eccentric counterbalanced drive in cast iron housing with 9 permanently lubricated ball bearings. Driven by solid-state brushless DC motor |
Shaking Speed | 25 to 500 rpm |
Shaker Type | Incubating Shaker |
Additional Model Specifications | Temperature accuracy and control: ± 0.1°C at 37°C with a nominal uniformity of ± 0.25°C Refrigeration: Innova 40R only. Hermetically-sealed compressor uses CFC-free refrigerant Heaters: Low watt-density, resistance heaters with high-temperature safety thermostat cut-out Timer and Parameter Control: 4 modes: - Speed and temperature continuous - Shaker can be set to run from 0.1 to 99.9 hours - On-board firmware can program multiple parameter changes to temperature and speed - Shaker control and data logging via RS-232 and remote computer running conventional laboratory management software or HyperTerminal Alarms, Audible and Visible: Indicate when speed deviates more than 5 rpm or temperature more than 1°C from setpoint, and when program or time has finished. Alarm may be muted Safety, Mechanical and Electronic: Acceleration circuit prevents sudden starts and stops. Sensor shuts off temperature when high-temperature limit is exceeded Setpoint Retention: Setpoints and operating status retained by non-volatile memory. Automatic restart after power is restored (indicated by flashing display). |