Hach Company - BioTector B3500c
Maximum uptime and reliability for TOC analysis in clean water applications
Plants can realize critical wall space savings that can be used for other instruments, due to an analyzer body which is roughly one-third the size of other TOC analyzers (one of the smallest footprints available). By needing to replenish reagents every six months instead of bi-weekly or monthly, and with the analyzer’s ability to monitor two streams at the same time, eliminating the need for two separate analyzers, operations will see direct savings to their bottom lines.
As the most reliable and affordable option available with the highest uptime, that provides immediate, direct savings, Hach’s BioTector B3500c is the industry’s choice when it comes to TOC analysis for clean water applications.
Active Questions & AnswersAsk a Question
There are no current Discussions
TOC Analyzers Service ProvidersView All (11)
Documents & Manuals
There are no Documents or Manuals available.
Features of BioTector B3500c
Worry-free TOC- With a patented Two Stage Advanced Oxidation Technology system, the B3500c provides you with maximum reliability and uptime, without sacrificing accuracy.
Lowest Cost of Ownership- Requiring you to replenish reagents, replace the pump tube, and calibrate only twice a year, the Hach BioTector B3500c has the lowest operating cost available.
Small Footprint = Critical Wall Space Savings- With one of the most compact analyzer footprints, this analyzer frees up wall space for other needed instruments.
Reagent Costs that Don't Kill the Bottom Line- By only needing to replenish reagents every six months, you will see direct bottom line savings in comparison to other systems requiring bi-weekly or monthly replacements.
One Instrument for Multiple Streams- Providing the ability to monitor two streams at the same time, eliminates the double-cost of needing two separate analyzers.
General Specifications
Depth | 12.6 in |
Measurement Range | 0 to 100 mg/L |
On-Line Monitoring | 1 |
Height | 29.5 in |
Width | 19.7 in |
NDIR | 1 |
Power Requirements | 50/60 Hz, 115/220 V AC |
Weight | 101.41 lbs |
Portable | 0 |
Additional Specifications
Ambient Temperature:
0 to 45 ºC (41 to 113 ºF)
Communication:
Modbus®, PROFIBUS, Ethernet
Modbus is a registered trademark of Gould Inc.
Cycle Time:
Typically 5 minutes 30 seconds
Data Storage:
Previous 9999 reaction data
Previous 99 fault events
Display:
High contrast 40 character x 16 line backlit LCD with LED backlight
EExp / Hazardous Location:
Certification options are available to North American Standards (Class 1, Div 2)
Exceedance Tracking:
Full exceedance tracking up to maximum range
Humidity:
5 to 85 %, non-condensing
Languages:
English, Spanish, French Others available upon request
Measurement Method:
Infrared Measurement of CO2 after Oxidation
Multi-Stream:
up to 2 process streams and grab sample
Oxidation Method:
Patented Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals
Particle Size:
Up to 100 µm
Permissible Chloride Range:
up to 30 %
Range:
0 to 100 mgC/L
Range Selection:
Automatic or Manual Range Selection
Repeatability:
± 3 % of reading or ± .03 mg/L (30 ppb) whichever is greater
Sample Inlet Temperature:
0 to 60 oC (36 - 140oF)
Service Interval:
6 month service intervals
User Interface Description:
Microcontroller with membrane keyboard