Features of TIM585
- Intelligent design ensures effortless setup and maintenance
- Intuitive interface guides you at every step
- One-touch selections and preprogrammed functions make titrations easy to run
- High-resolution burette, unique addition technique and special algorithms ensure accurate results
- Assistant function and extensive data storage give complete confidence in your results
General Specifications
Depth | 18 in |
Height | 15 in |
mV Resolution | 0.1 mV |
Width | 9.1 in |
Power Requirements | 47.5 - 63 Hz, 115/220 V AC |
Weight | 11.02 lbs |
Titrator Type | Karl Fischer Volumetric |
Additional Specifications
Automatic Reagent Addition(s):
1 prior titration starts
Balance:
Serial RS232, Direct & double weighing technique supported
Beaker Volumes Accepted:
35 to 150 mL Clear or brown glass beaker, standard or thermostated
Burette Max Permissible Errors:
Random and Systematic: Both Comply with ISO8655-3…..Random Error:
± 0.05 - 0.1 % ……Systematic Error: ± 0.2 - 0.6 %
Burette motor resolution:
18000
Burette: Stand / Tap Type:
Fixed
Burette: Volumes Available:
1 ml, 5 ml, 10 ml, 25 ml & 50 ml
Calibration Interval:
from 1 to 999 days
Compliance:
CE marking
cETLus certification
Continuous Dynamic Titrant Addition:
Addition speed from 0.01 to 50 mL/min
Display Type:
Graphic 128x128 dot LCD protected from spillages with TPX cover
Embedded Titrating / Dosing Unit(s):
2 embedded burette motors
End Point Titration:
1 EP - Karl Fischer End Point
Internal Calibration Storage Capacity:
Last 100 FIFO management
Internal Data Storage:
Last 200 FIFO management
Internal Method Storage Capacity:
50
IP Rating:
Fully splashproof chemical resistant lathene
Languages:
English, German, Danish, French, Italian, Spanish, Swedish
Method ID:
Up to 16 characters, alphanumeric
Non-Volatile Memory:
Battery saved
Operating Humidity:
20 to 80 %
Operating Interface:
Rubber soft touch alphanumeric keypad.
Operating Temperature:
5 to 40 °C
Password Protection:
Up to 10 characters, alphanumeric
PC Data Transfer Software:
Serial RS232, TitraMaster 85
Printer:
Serial RS232
QC Sample Management:
with acceptation limits
Result ID: U
p to 16 characters, alphanumeric
Sample Changer:
Serial RS232, with SAC850 & SAC950
Sample Changer Stack:
up to 126 samples
Sample ID:
Up to 16 characters, alphanumeric
Sample Results:
up to 4 results per analysis with acceptation criteria
Sample Stand:
Embedded with magnetic stirring
Temperature Resolution:
0.1 °C
Titrant Calibration:
with acceptance criteria
TTL Input / Output:
1 Input/2 Ouputs 0-5V & 0-12V
User Defined Sample Result Calculations:
2 equations per analysis with acceptation criteria
User ID:
Up to 16 characters, alphanumeric
User Programs:
6 Preprogrammed
Volumetric Karl Fischer Titration:
with cell conditioning & stand by mode