Hach Company - TIM585

Manufactured by  Hach Company
Follow this Equipment

TIM585 is a dual burette with integrated solvent handling pump for rountine Karl Fischer titrator for moisture content...

TIM585 is a dual burette with integrated solvent handling pump for rountine Karl Fischer titrator for moisture content determination in solid or liquid samples.
Active Questions & AnswersAsk a Question

There are no current Discussions

Titrators Service ProvidersView All (5)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of TIM585
  • Intelligent design ensures effortless setup and maintenance 
  • Intuitive interface guides you at every step 
  • One-touch selections and preprogrammed functions make titrations easy to run 
  • High-resolution burette, unique addition technique and special algorithms ensure accurate results 
  • Assistant function and extensive data storage give complete confidence in your results
General Specifications
Depth 18 in
Height15 in
mV Resolution0.1 mV
Width 9.1 in
Power Requirements 47.5 - 63 Hz, 115/220 V AC
Weight11.02 lbs
Titrator TypeKarl Fischer Volumetric
Additional Specifications

Automatic Reagent Addition(s):  
1 prior titration starts 
Balance:  
Serial RS232, Direct & double weighing technique supported 
Beaker Volumes Accepted:  
35 to 150 mL Clear or brown glass beaker, standard or thermostated 
Burette Max Permissible Errors:  
Random and Systematic: Both Comply with ISO8655-3…..Random Error:  
± 0.05 - 0.1 % ……Systematic Error: ± 0.2 - 0.6 % 
Burette motor resolution:  
18000 
Burette: Stand / Tap Type:  
Fixed 
Burette: Volumes Available:  
1 ml, 5 ml, 10 ml, 25 ml & 50 ml 
Calibration Interval:  
from 1 to 999 days 
Compliance:  
CE marking 
cETLus certification 
Continuous Dynamic Titrant Addition:  
Addition speed from 0.01 to 50 mL/min 
Display Type:  
Graphic 128x128 dot LCD protected from spillages with TPX cover 
Embedded Titrating / Dosing Unit(s):  
2 embedded burette motors 
End Point Titration:  
1 EP - Karl Fischer End Point 
Internal Calibration Storage Capacity:  
Last 100 FIFO management 
Internal Data Storage:  
Last 200 FIFO management 
Internal Method Storage Capacity:  
50 
IP Rating:  
Fully splashproof chemical resistant lathene 
Languages:  
English, German, Danish, French, Italian, Spanish, Swedish 
Method ID:  
Up to 16 characters, alphanumeric 
Non-Volatile Memory:  
Battery saved 
Operating Humidity:  
20 to 80 % 
Operating Interface:  
Rubber soft touch alphanumeric keypad. 
Operating Temperature:  
5 to 40 °C 
Password Protection:  
Up to 10 characters, alphanumeric 
PC Data Transfer Software:  
Serial RS232, TitraMaster 85 
Printer:  
Serial RS232 
QC Sample Management:  
with acceptation limits 
Result ID:
p to 16 characters, alphanumeric 
Sample Changer:  
Serial RS232, with SAC850 & SAC950 
Sample Changer Stack:  
up to 126 samples 
Sample ID:  
Up to 16 characters, alphanumeric 
Sample Results: 
up to 4 results per analysis with acceptation criteria 
Sample Stand: 
Embedded with magnetic stirring 
Temperature Resolution:  
0.1 °C 
Titrant Calibration:  
with acceptance criteria 
TTL Input / Output:  
1 Input/2 Ouputs 0-5V & 0-12V 
User Defined Sample Result Calculations:  
2 equations per analysis with acceptation criteria 
User ID:  
Up to 16 characters, alphanumeric 
User Programs:  
6 Preprogrammed 
Volumetric Karl Fischer Titration:  
with cell conditioning & stand by mode

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com