The detector has a double-beam, grating monochromator and dual photodiode sensor. Wavelength Range: 190-800...

The detector has a double-beam, grating monochromator and dual photodiode sensor. Wavelength Range: 190-800 nm. 
 
The solvent delivery modules are built with the digitally controlled rapid refill pump design with automatic compressibility compensation that has received multiple patents. These features produce smooth flow from microbore to semi-preparative flow rates, and the high-pressure mixing design eliminates the need for constant helium sparging or degassing. The pumps are combined with high-sensitivity UV/VIS and diode array detectors and autosamplers with automation capability to build HPLC systems that have a reputation for the best performance, ease of use and troubleshooting, and longevity due to a solid and reliable design
Active Questions & AnswersAsk a Question

UV/VIS Detector Service ProvidersView All (21)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features

There are no Features available.

General Specifications
Depth 52.1 cm
Height20.3 cm
Width 30.5 cm
Power Requirements 90 to 130 VAC
Weight10 kg
Additional Specifications

Beckman 166 UV-VIS Detector (p/n 728166) Specifications  
UNSPSC:41115701  
Mercury Content:Item Contains Mercury - Dispose According to State/Local Law  
Bandwidth:< 5nm @ 254  
Detector:Double-beam, grating monochromator, dual photodiode sensor  
Drift Analytical Flow  
Cell:  
< 0.0001 AU/hr at constant temperature  
Electrical:90 to 130 VAC or 198 to 254 VAC, 50 or 60 Hz, 130 watts, 2 Amps  
Environment:Ambient temperature 4° C to 40° C  
Light Source: 
UV-pre-aligned D2 lamp 190-360 or 361-700 nm, Visible-optional tungsten lamp 361-700 nm  
Linearity Analytical Flow  
Cell:  
± 1% from 0.1 to 1.0 AU to ± .001 AU below 0.1 AU ± 5% from 1.0 to 1.5 AU  
Material:Stainless Steel  
Maximum Back Pressure:1,000 psi  
Memory Protection:Battery back up maintains parameters for 1 week  
Noise Analytical Flow  
Cell:  
< 0.00002AU peak-to-peak 1.1 second rise time at 220- 280 nm, 1 mL/min methanol  
Optional Flow Cell:Micro 4 µL/5mm/ss, Prep 2.8 µL/0.5mm/ss  
Path Length:10 mm  
Programmable Audible  
Alarms Function (Standard or Programmable): Yes  
Programmable Auto Zero Function: Yes  
Programmable Bandwidth Function: Yes  
Programmable Event Mark Function: Yes  
Programmable Lamp Off Function: Yes  
Programmable Peak Threshold Function: Yes  
Programmable Range Function: Yes  
Programmable Relays On/Off Function: Yes  
Programmable Rise Time Function: Yes  
Programmable Scan Storage Function: No  
Programmable Stop Data Function: Yes  
Programmable Wavelength Function: Yes  
Rise Time:Selectable 0-5 seconds  
U.P.S Load:2 Amps  
Wavelength Accuracy:± 2 nm after calibration  
Wavelength Range:190-800 nm Single Channel,  
Programmable, Req. Tungsten Lamp for Visible