Hach Company - DR 6000
The DR6000™ is the industry’s most advanced lab spectrophotometer. It offers high speed wavelength scanning...
Combining the DR6000 with Hach’s patented TNTplus™ reagent vials, you gain additional accuracy with guided step-by-step testing procedures, while making scratched, flawed or dirty glassware a non-issue due to 10 reading averages and the discarding of outliers. The instrument also utilizes RFID technology, allowing it to automatically let you know if your TNTplus reagents have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries.
Partnering all of these features with an integrated QA software package allows for scheduling, documenting and interpreting your needed quality measurements.
Your water testing needs, all in one spectrophotometer.
*RFID currently available only in US, Canada, Puerto Rico, Australia, New Zealand, and Colombia. Customers in other countries should order LPV441.99.00002.
Active Questions & AnswersAsk a Question
Post
self check error [33-]
solution
UV/VIS Spectrophotometers Service ProvidersView All (32)
Documents & Manuals
There are no Documents or Manuals available.
Features of DR 6000
Your Water Testing Needs, All in One Spectrophotometer The DR 6000 has the most pre-programmed testing methods, including high speed wavelength scanning across the UV and Visible Spectrum.
Accessories for High Volume and High Accuracy Testing Needs A carousel sample changer allows for up to seven sequential measurements. The Sipper Module, an instrument controlled sample delivery system, increases precision by constant optical characteristics.
Advanced Quality Assurance at Your Fingertips The DR 6000 comes with integrated QA software for scheduling, documenting and interpreting all of your needed quality measurements.
Guided Procedures and Elimination of False Readings The DR 6000, when used with TNTplus® reagent vials provides you the accurate results you need by guiding you step-by-step through your testing procedures. With TNTplus the instrument averages 10 readings and eliminating outliers, making scratched, flawed or dirty glassware a non-issue.
Automatically Avoids Errors RFID* technology automatically updates the program calibration factors when you place a TNTplus reagent box near the DR 6000. The instrument identifies chemistry expiration dates via a barcode on the vials, and detcts chemistry coefficient factors to avoid errors that can occur in lot-to-lot variations in the chemistry. *RFID technology currently available in US, Canada, Australia and New Zealand only.
General Specifications
There are no General Specifications available.
Series Modals
Hach Company - DR 6000 with RFID Technology
[+] View Model SpecificationsBandwidth | 2 nm |
Depth | 460 mm |
Height | 215 mm |
Width | 500 mm |
Power Requirements | 100 - 240 V; 50/60 Hz |
Photometric Range | ± 3 Abs |
Weight | 11 kg |
Part Number | LPV441.99.00012 |
Wavelength Range | 190 to 1100 nm |
Scanning Speed | 900 nm/min (in 1 nm steps |
Light Source | Tungsten (visible range), deuterium (UV range) |
Stray Light | KI-solution at 220 nm < 3.3 Abs/ < 0.05% |
Wavelength Resolution | 0.1 nm |
Additional Model Specifications | Operating Conditions: 10 to 40 °C, max. 80% relative humidity (non-condensing) Wavelength Accuracy: ± 1 nm Wavelength Reproducibility: < 0.1 nm Wavelength Selection: Automatic, based on method selection Photometric Accuracy: <1% at 0.5-2.0 Abs at 546 nm 5 mAbs at 0.0-0.5 Abs Photometric Linearity: 0.5 % - 2 Abs Photometric Linearity 2: 1 % at > 2 Abs with neutral glass at 546 nm Optical System: reference beam, spectral Manual Languages: en, es, fr, ja, ko, pt, zh |
Hach Company - DR6000 without RFID Technology
[+] View Model SpecificationsDepth | 460 mm |
Height | 215 mm |
Width | 500 mm |
Power Requirements | 100 - 240 V |
Weight | 11 kg |
Part Number | LPV441.99.00002 |
Wavelength Range | 190 to 1100 nm |
Light Source | Tungsten (visible range), deuterium (UV range) |
Stray Light | KI-solution at 220 nm < 3.3 Abs/ < 0.05% |
Wavelength Resolution | 0.1 nm |
Additional Model Specifications | Cuvette Compatibility 2: 1 inch rectangular and round cell Cuvette Compatibility 3: optional 100 mm rectangular cell with additional adapter Operating Conditions: 10 to 40 °C, max. 80% relative humidity (non-condensing) Wavelength Accuracy: ± 1 nm Wavelength Reproducibility: < 0.1 nm Wavelength Selection: Automatic Photometric Accuracy: 5 mAbs at 0.0-0.5 Abs Photometric Linearity: 0.5 % - 2 Abs Photometric Linearity 2: 1 % at > 2 Abs with neutral glass at 546 nm Optical System: reference beam, spectral Manual Languages: en, es, fr, ja, ko, pt, zh |