Our reliable direct heat Steri-Cycle® CO2 incubator combines the best of both worlds - our unique in-chamber HEPA air filtration system providing continuous protection against unwanted airborne contaminants and an on-demand, high temperature sterilization cycle, to simplify your routine cleaning practices.
Active Questions & AnswersAsk a Question
4Replies
Door closure sensor on Mother board
2Replies
condensation
2Replies
temperature calibration problem
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of Forma Steri-Cycle
Providing precise CO2 control with choice of TC (thermal conductivity) or IR (infrared) sensor, excellent temperature uniformity and recovery characteristics, the Steri-Cycle is a favorite of researchers seeking the benefits of complete contamination control and dependable long term performance.
Key Accessories:
- Interior Components
- Copper Interior Kits
- HEPA Filters & Cleaning Kits
- Roller dollies and stands
- Built-In Gas Guards
- Factory-Installed Data Outputs
- Gas Regulators
General Specifications
There are no General Specifications available.
Additional Specifications
Temperature Range : +5C above ambient to +50C
Temperature Uniformity : +/-0.3C @ 37C
Humidity System : 3.2 quart (3.0 liter) pan
Humidity Range : Ambient to 95% @ 37C
Interior Volume : 6.5 cu.ft. (184.1 liters)
Interior W x H x F-B : 21.3
Series Modals
Thermo Scientific - 370 & 371
[+] View Model SpecificationsCO2 Incubator Type | Direct Heat |
Depth | 25 in |
Humidity | Ambient to 95% @ 37°C (98.6F) |
Temperature Uniformity | 0.3 °C |
Height | 39.5 in |
Internal Depth | 20 in |
Internal Height | 26.8 in |
Width | 26.3 in |
Internal Width | 21.3 in |
Chamber Volume | 6.5 cu. ft. |
CO2 Sensor | Thermal Conductivity (TC) |
CO2 Range | 0 to 20 % |
Weight | 260 lbs |
Shipping Weight | 315 lbs |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 18.5 |
Temperature Accuracy | 0.1 °C |
Construction | Interior: Type 304, polished stainless steel. Exterior: 18 gauge, cold-rolled steel, powder coated. Outer door gasket: Four-sided, molded, magnetic vinyl. Inner door gasket: Removable, cleanable, feather-edged, silicone. Shelves: Stainless steel, perforated |
Incubator Orientation | Benchtop |
Additional Model Specifications | Power Supply: 370: 115V, 50/60 Hz, 9.6 FLA (Operating range 90-125V), 12 Amps/2 Pole 371: 230V, 50/60 Hz, 4.4 FLA (Operating range 180-250V), 12 Amps/2 Pole Temperature Tracking Alarm: User-programmable low Overtemperature Sensor: Precision thermistor Overtemperature Setability: 0.1°C Overtemperature Function: Shuts off heat Sterilization Cycle Sensor: Precision thermistor Sterilization cycle temperature: 140°C Sterilization Cycle Length: Under 12 hours CO2 Inlet pressure: 15 PSIG (1.0 bar) Readability & Setability: 0.1% Tracking Alarm: User-programmable high-low Humidity Humidity Pan: 3.2 qt. (3.0 liters) standard Display (opt.): In 1% increments Fittings Access port: 1.3" (3.3cm) with removable silicone plug with filter CO2 Inlet: 1/4" hose (barbed) Unit Heat Load 115V/230V: 293 BTUH (86 Watts) |
Thermo Scientific - 380 & 381
[+] View Model SpecificationsCO2 Incubator Type | Direct Heat |
Depth | 25 in |
Humidity | Ambient to 95% @ 37°C (98.6F) |
Temperature Uniformity | 0.3 °C |
Height | 39.5 in |
Internal Depth | 20 in |
Internal Height | 26.8 in |
Width | 26.3 in |
Internal Width | 21.3 in |
Chamber Volume | 6.5 cu. ft. |
CO2 Sensor | Thermal Conductivity (TC) |
Weight | 260 lbs |
Shipping Weight | 315 lbs |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 18.5 |
Construction | Interior: Type 304, polished stainless steel. Exterior: 18 gauge, cold-rolled steel, powder coated. Outer door gasket: Four-sided, molded, magnetic vinyl. Inner door gasket: Removable, cleanable, feather-edged, silicone. Shelves: Stainless steel, perforated |
Incubator Orientation | Benchtop |
Additional Model Specifications | Power Supply: 380: 115V, 50/60 Hz, 9.6 FLA (Operating range 90-125V), 12 Amps/2 Pole 381: 230V, 50/60 Hz, 4.4 FLA (Operating range 180-250V), 12 Amps/2 Pole Temperature Tracking Alarm: User-programmable low Overtemperature Sensor: Precision thermistor Overtemperature Setability: 0.1°C Overtemperature Function: Shuts off heat Sterilization Cycle Sensor: Precision thermistor Sterilization cycle temperature: 140°C Sterilization Cycle Length: Under 12 hours CO2 Inlet pressure: 15 PSIG (1.0 bar) Readability & Setability: 0.1% Tracking Alarm: User-programmable high-low Humidity Humidity Pan: 3.2 qt. (3.0 liters) standard Display (opt.): In 1% increments Fittings Access port: 1.3" (3.3cm) with removable silicone plug with filter CO2 Inlet: 1/4" hose (barbed) Unit Heat Load 115V/230V: 293 BTUH (86 Watts) |