Thermo Scientific - Forma Series II 3110
Forma Series II 3110 Water Jacketed CO2 Incubator
Active Questions & AnswersAsk a Question
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of Forma Series II 3110
Proven Water Jacket Technology Temperature retention and quick recovery are especially important for researchers working with critical cell cultures. Our water jacketed incubator provides maximum thermal protection and quick recovery from swings in ambient temperature and power variations.
Durable triple wall cabinet construction ensures optimal temperature uniformity. The Series II water jacketed holds temperature longer and recovers to a uniform interior value more quickly than any other technology available today.
Patented, heated dual pane inner glass door minimizes bothersome condensation with improved responsiveness and faster temperature recovery. Do You Trust Your Power Supply? Power outages can be detrimental to your cultures. If you aren’t completely confident in your power supply, consider the security of a Series II Incubator.
Product testing during a power failure in an 18°C (64.4F) ambient resulted in the water jacketed incubator’s temperature gradually dropping only 1°C – from 37°C to 36°C (98.6F to 96.8F) – in 1 hour and approximately 7.6°C in 10 hours.
The air jacketed incubator’s temperature dropped 3°C – from 37°C to 34°C (98.6F to 93.2F) – in 1 hour and 17°C in 10 hours.
Easy to Configure and Use Quality construction. Reliable performance. Intuitive controls shared by other products with the Forma name. The Series II Incubator is designed for long life and ease of use.
Control O2 Within the Culture Environment researchers seeking to experiment with the effect of suppressed oxygen concentration upon their cultures can select a Series II model with both CO2 and O2 control capabilities. Individual O2 display facilitates set point and monitoring of desired O2 levels in a range of 0 – 20% for hypoxic studies.
General Specifications
CO2 Incubator Type | Water Jacketed |
Depth | 25 in |
Humidity | Ambient to 95% at 37°C |
Height | 39.5 in |
Internal Depth | 20 in |
Internal Height | 26.8 in |
Width | 26 in |
Internal Width | 26 in |
Chamber Volume | 6.5 cu. ft. |
CO2 Range | 0 to 20 % |
Weight | 265 lbs |
Incubator Orientation | Benchtop |
Additional Specifications
Humidity System: 3L stainless-steel pan
Temperature Uniformity: ±0.2°C at 37°C
Chamber: Polished stainless-steel interior with coved corners
Shelving:Stainless steel
Port(s): Chamber thru-wall access port with filter; RS-485 interface (optional)
Shipping Weight: 324 lb. (147kg)