PHCBi - SafeCell™ UV Series
MCO-20AIC: 7.6 cu. ft. CO2 Cell Culture Incubator with SafeCell™ UV
Professional CO2 Cell Culture Incubator
- Eliminates Chronic In Vitro Contamination Without Downtime
- Passive Resistance To Mycoplasma
- Integrated Core Technologies For Maximum Performance
- Introducing Active Background Contamination Control™
- For Greater Productivity In Research and Clinical Applications
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byPatzi
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of SafeCell™ UV Series
General Features
- ActiveBackground Contamination Control
- SANYO inCu saFe™ copper-alloy-stainless interior, shelves and plenum
- Patented Direct Heat, Air™(DHA) Incubator Heating System
- More useable space with HEPA filters located out of chamber
- Polyurethane insulation barrier
- Direct Heat (Air)™ air jacket surrounding chamber allows uniform temperature distribution with no temperature gradients
- Direct heating elements blanket the chamber
- Independent bottom heater adjustment allows relative decrease in RH level
- Door heater prevents condensation on glass inner door
- Tempered glass inner door allows sample viewing
General Specifications
There are no General Specifications available.
Additional Specifications
Heating System
Method: Patented Direct Heat and Air Jacket
Heating Elements: 395 watts per chamber
Temperature Control: Microprocessor controlled PID
Digital Temperature Display: resolution 0.1°C
CO2 System
CO2 Sensor: ceramic based infared (I.R.)
CO2 System Electronics: microprocessor
CO2 Setpoint and Resolution: ±0.1%
CO2 Inlet Connect/Pressure: 5 PSIG, 0.03 MpaG
CO2 Switchover System: optional
Humidification System
Method: natural evaporation
Relative Humidity: 95 +/-5% (ambient temperature 37°C, CO2, 5%)
Water Level Sensor: Optical, low water level alarm
Series Modals
PHCBi - MCO-18AIC(UV), MCO-36AIC(UV)
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 28 in |
Humidity | 95+/-5% (ambient temp. 37°C, CO2 5%) |
Temperature Uniformity | 0.25 °C |
Height | 35.4 in |
Internal Depth | 20.6 in |
Internal Height | 26.2 in |
Width | 24.4 in |
Internal Width | 19.3 in |
Power Requirements | 115V, AC, 60Hz, NEMA 5-15 |
Chamber Volume | 6 cu. ft. |
CO2 Sensor | Infrared (IR) |
CO2 Range | 0 to 20 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 17.7 |
Construction | Interior surface: inCu saFe™ copper-enriched stainless steel alloy for germicidal protection. Exterior cabinet: polyester finished, baked-on zinc galvanized steel, reinforced for stacking. Inner door: tempered glass with positive latch. Outer door: left hand swing standard, reversible to right hand swing |
Incubator Orientation | Benchtop |
Additional Model Specifications | Heating System Method: Patented Direct Heat and Air Jacket™ Heating Elements: 314 watts per chamber Temperature Control: microprocessor controlled P.I.D. Digital Temperature Display: resolution 0.1ºC CO2 System CO2 System Electronics: microprocessor P.I.D./R CO2 Setpoint and Resolution: ±0.1% CO2 Inlet Connect/Pressure: 5 PSIG, 0.03MpaG CO2 Switchover System: optional Humidification System Method: natural evaporation Water Level Sensor: optical, low water level alarm Exterior dimensions, stacked: 30.3"W x 27.9"F-B x 70.8"H Contamination Control SafeCell™ UV System: standard inCu saFe™ Interior: standard Decontamination Method: programmable UV sterilization of air and water pan UV Lamp: 4 watt, 253.7 nanometer narrow bandwidth, ozone-free Microbiological Filters: 0.3 microns, 99.97% efficient, on air and CO2 inputs Control, Alarm, Monitoring and Electrical Microprocessor Control: SANYO-built electronic components Control Position: door-mounted, eye-level location on dual stacked configuration Alarm System: Overtemp., CO2 and temperature deviation, low water level, door ajar, lamp failure alarm Remote Alarm Contacts: 30V DC, 2 amps allowable Communications (Optional): MCO-420MA data port available, 4 to 20 MA signal |
PHCBi - MCO-20AIC, MCO-40AIC
[+] View Model SpecificationsCO2 Incubator Type | Air Jacketed |
Depth | 24.9 in |
Humidity | 95%, ±5% (ambient temp. 37°C, CO2 5%) |
Temperature Uniformity | 0.25 °C |
Height | 35.4 in |
Internal Depth | 20.6 in |
Internal Height | 26.2 in |
Width | 30.3 in |
Internal Width | 24.4 in |
Power Requirements | 115V, AC, 60Hz, NEMA 5-15 |
Chamber Volume | 7.6 cu. ft. |
CO2 Sensor | Infrared (IR) |
CO2 Range | 0 to 20 % |
CO2 Accuracy | 0.1 % |
Shelf Dimensions | 22.8 |
Construction | Interior surface: inCu saFe™ copper-enriched stainless steel alloy for germicidal protection. Exterior cabinet: polyester finished, baked-on zinc galvanized steel, reinforced for stacking. Inner door: tempered glass with positive latch.Outer door: left hand swing standard, reversible to right hand swing |
Incubator Orientation | Benchtop |
Additional Model Specifications | Heating System Method: Patented Direct Heat and Air Jacket™ Heating Elements: 395 watts per chamber Temperature Control: microprocessor controlled P.I.D. Digital Temperature Display: resolution 0.1ºC CO2 System CO2 System Electronics: microprocessor CO2 Setpoint and Resolution: ±0.1% CO2 Inlet Connect/Pressure: 5 PSIG, 0.03MpaG CO2 Switchover System: optional Humidification System Method: natural evaporation Water Level Sensor: optical, low water level alarm Exterior dimensions, stacked: 30.3"W x 27.9"F-B x 70.8"H Contamination Control SafeCell™ UV System: standard inCu saFe™ Interior: standard Decontamination Method: programmable UV sterilization of air and water pan UV Lamp: 4 watt, 253.7 nanometer narrow bandwidth, ozone-free Microbiological Filters: 0.3 microns, 99.97% efficient, on air and CO2 inputs Control, Alarm, Monitoring and Electrical Microprocessor Control: SANYO-built electronic components Control Position: door-mounted, eye-level location on dual stacked configuration Alarm System: Overtemp., CO2 and temperature deviation, low water level, door ajar Remote Alarm Contacts: 30V DC, 2 amps allowable Communications (Optional): MCO-420MA data port available, 4 to 20 MA signal |