Siemens - Protegra CS
Manufactured by Siemens
Water Purification Systems that combine reverse osmosis with electro-deionization to produce analytical grade, high purity water.
Protegra CS™ systems from Siemens Water Technologies produces analytical grade, type II water for many of today's modern laboratory, healthcare and industrial applications.
Whether you're looking for steady and reliable water for your clinical or analytical laboratories, or have a quality control, pharmaceutical, or cosmetic lab that requires type II water at flow rates of 120 - 170 liters per hour, you can rely on water produced by the new Protegra CS™ system. Our systems combine reverse osmosis (RO) and electro-deionization (CEDI) technology to produce a highly consistent quality water.
All parts (Prefilter, RO,CEDI, and RO pump) are contained in one cabinet. And, our Protegra CS™ Systems from Siemens are validatable.
RO and CEDI
Our high capacity RO membrane is designed to produce a high recovery rate and remove dissolved solids from your water source while sending less reject water to the drain. The CEDI module continually regenerates itself without acids or alkalis. Both technologies combine to produce reliable and consistent quality water, cost effectively and with less interruption (less maintenance) - a perfect choice for type II water.
Whether you're looking for steady and reliable water for your clinical or analytical laboratories, or have a quality control, pharmaceutical, or cosmetic lab that requires type II water at flow rates of 120 - 170 liters per hour, you can rely on water produced by the new Protegra CS™ system. Our systems combine reverse osmosis (RO) and electro-deionization (CEDI) technology to produce a highly consistent quality water.
All parts (Prefilter, RO,CEDI, and RO pump) are contained in one cabinet. And, our Protegra CS™ Systems from Siemens are validatable.
RO and CEDI
Our high capacity RO membrane is designed to produce a high recovery rate and remove dissolved solids from your water source while sending less reject water to the drain. The CEDI module continually regenerates itself without acids or alkalis. Both technologies combine to produce reliable and consistent quality water, cost effectively and with less interruption (less maintenance) - a perfect choice for type II water.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byjwoolridge
Water Purification Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of Protegra CS
Advantages of Protegra CS™ Systems
- Efficient reverse osmosis and electro-deionization technology
- Minimal maintenance with less interruptions
- High recovery rates
- Lower TOC
- Less bacterial growth
Markets Best Served
- Bio-technology
- Life Science Laboratories
- Quality Control Labs
- Pharmaceutical
- Cosmetic Industry
- Clinical Laboratories
- Pretreatment for ultra pure systems
- Industrial Usages
- Analytical Research Laboratories
General Specifications
There are no General Specifications available.
Series Modals
Siemens - PROTC120A
[+] View Model SpecificationsDepth | 27 in |
Flow Rate | 113.5 L/hr |
Height | 64 in |
Width | 24 in |
Power Requirements | 120 VAC, 13.0 FLA, 2/4 HP |
Water Purification Method | RO |
Shipping Weight | 350 lbs |
ASTM Type | ASTM Type II |
Additional Model Specifications | Feed LPH (gpm): 227 (1) Final Product - maximum LPH (gpm): 113.5 (0.5) RO Reject LPH (gpm): 84 (0.37) CEDI Reject LPH (gpm): 11 (0.05) Reject Recycle LPH (gpm): 681.3 (3) Membrane quantity: 1 Vessel quantity: 1 Feed Water Requirements* Maximum SDI rating: 3 Maximum turbidity: 1 NTU Maximum Free Chlorine and / or chloramines: < 0.02 ppm pH (continuous): 4 – 11 pH (cleaning - 30 min.): 1 – 12 *If any of the feed water parameters are not within the limits given, consult the factory for application assistance. Operating Parameters* System Inlet Pressure: 30–90 psig (3.44 bars) Design Membrane Feed Pressure @ 77°F (25°C): 125 psig nominal (8.61 bars) *If any of the operating conditions are not within the limits given, consult the factory for application assistance. Operation below the design feed water temperature of 77°F may de-rate the product flow or require a larger booster pump. Design Parameters Configuration: Single Pass RO and CEDI Inlet Pressure Requirements: 29-87 psig (2-6 bars) Feed Water Source: Softened Municipal Pre-filtration Requirements: 5µm nominal Feed Water Fouling Index: Silt Density Index (SDI) < 3 System Recovery (Nominal): 60% Product Pressure Available: 25 psig (1.72 bars) Membrane Salt Rejection: 99% nominal |
Siemens - PROTC260A
[+] View Model SpecificationsDepth | 27 in |
Flow Rate | 454 L/hr |
Height | 64 in |
Width | 24 in |
Power Requirements | 120 VAC, 13.0 FLA, 3/4 HP |
Water Purification Method | RO |
Shipping Weight | 675 lbs |
ASTM Type | ASTM Type II |
Additional Model Specifications | Feed LPH (gpm): 454 (2) Final Product - maximum LPH (gpm): 249 (1.1) RO Reject LPH (gpm): 181.6 (0.8) CEDI Reject LPH (gpm): 22.7 (0.1) Reject Recycle LPH (gpm): 454 (2) Membrane quantity: 2 Vessel quantity: 2 Feed Water Requirements* Maximum SDI rating: 3 Maximum turbidity: 1 NTU Maximum Free Chlorine and / or chloramines: < 0.02 ppm pH (continuous): 4 – 11 pH (cleaning - 30 min.): 1 – 12 *If any of the feed water parameters are not within the limits given, consult the factory for application assistance. Operating Parameters* System Inlet Pressure: 30–90 psig (3.44 bars) Design Membrane Feed Pressure @ 77°F (25°C): 125 psig nominal (8.61 bars) *If any of the operating conditions are not within the limits given, consult the factory for application assistance. Operation below the design feed water temperature of 77°F may de-rate the product flow or require a larger booster pump. Design Parameters Configuration: Single Pass RO and CEDI Inlet Pressure Requirements: 29-87 psig (2-6 bars) Feed Water Source: Softened Municipal Pre-filtration Requirements: 5µm nominal Feed Water Fouling Index: Silt Density Index (SDI) < 3 System Recovery (Nominal): 60% Product Pressure Available: 25 psig (1.72 bars) Membrane Salt Rejection: 99% nominal |
Siemens - PROTC500A
[+] View Model SpecificationsDepth | 27 in |
Flow Rate | 499 L/hr |
Height | 64 in |
Width | 24 in |
Power Requirements | 120 VAC, 16.2 FLA, 3/4 HP |
Water Purification Method | RO |
Shipping Weight | 400 lbs |
ASTM Type | ASTM Type II |
Additional Model Specifications | Feed LPH (gpm): 908 (4) Final Product - maximum LPH (gpm): 499 (2.2) RO Reject LPH (gpm): 363 (1.6) CEDI Reject LPH (gpm): 45.4 (0.2) Reject Recycle LPH (gpm): 340.6 (1.5) Membrane quantity: 3 Vessel quantity: 3 Feed Water Requirements* Maximum SDI rating: 3 Maximum turbidity: 1 NTU Maximum Free Chlorine and / or chloramines: < 0.02 ppm pH (continuous): 4 – 11 pH (cleaning - 30 min.): 1 – 12 *If any of the feed water parameters are not within the limits given, consult the factory for application assistance. Operating Parameters* System Inlet Pressure: 30–90 psig (3.44 bars) Design Membrane Feed Pressure @ 77°F (25°C): 125 psig nominal (8.61 bars) *If any of the operating conditions are not within the limits given, consult the factory for application assistance. Operation below the design feed water temperature of 77°F may de-rate the product flow or require a larger booster pump. Design Parameters Configuration: Single Pass RO and CEDI Inlet Pressure Requirements: 29-87 psig (2-6 bars) Feed Water Temperature: 45°F – 90°F (5°C – 35°C) Feed Water Source: Softened Municipal Pre-filtration Requirements: 5µm nominal Feed Water Fouling Index: Silt Density Index (SDI) < 3 System Recovery (Nominal): 60% Product Pressure Available: 25 psig (1.72 bars) Membrane Salt Rejection: 99% nominal |
Siemens - PROTC750B
[+] View Model SpecificationsDepth | 27 in |
Flow Rate | 749.5 L/hr |
Height | 64 in |
Width | 24 in |
Power Requirements | 120 VAC, 11.5 FLA, 3/4 HP |
Water Purification Method | RO |
Shipping Weight | 440 lbs |
ASTM Type | ASTM Type II |
Additional Model Specifications | Feed LPH (gpm): 1362 (6) Final Product - maximum LPH (gpm): 749.5 (3.3) RO Reject LPH (gpm): 545 (2.4) CEDI Reject LPH (gpm): 68 (0.3) Reject Recycle LPH (gpm): 227 (1) Membrane quantity: 4 Vessel quantity: 4 Feed Water Requirements* Maximum SDI rating: 3 Maximum turbidity: 1 NTU Maximum Free Chlorine and / or chloramines: < 0.02 ppm pH (continuous): 4 – 11 pH (cleaning - 30 min.): 1 – 12 *If any of the feed water parameters are not within the limits given, consult the factory for application assistance. Operating Parameters* Feed Temperature: 45°F – 90°F (5°C – 35°C) System Inlet Pressure: 30–90 psig (3.44 bars) Design Membrane Feed Pressure @ 77°F (25°C): 125 psig nominal (8.61 bars) *If any of the operating conditions are not within the limits given, consult the factory for application assistance. Operation below the design feed water temperature of 77°F may de-rate the product flow or require a larger booster pump. Design Parameters Configuration: Single Pass RO and CEDI Inlet Pressure Requirements: 29-87 psig (2-6 bars) Feed Water Temperature: 45°F – 90°F (5°C – 35°C) Feed Water Source: Softened Municipal Pre-filtration Requirements: 5µm nominal Feed Water Fouling Index: Silt Density Index (SDI) < 3 System Recovery (Nominal): 60% Product Pressure Available: 25 psig (1.72 bars) Membrane Salt Rejection: 99% nominal |