Features of BioPROtect series
BioProtect® Equipment Containment Enclosures Class II Style, for Type A2 Applications Walk-in clean air and containment enclosure Available in two sizes Designed expressly for high volume robotic and equipment applications With a flexible modular design, the BioPROtect® III and BioPROtect® Jr. are Class II style clean air and biocontainment enclosures designed for high-volume robotic and automated equipment applications. The BioPROtect® air containment unit accommodates high-throughput robotic systems (including ancillary devices), ultra-centrifuges, flow cytometers, aerosol generators and other large laboratory equipment. Both models are ideal for high-throughput screening, combinatorial chemistry, immunology, tissue culture, clinical research, drug discovery, molecular biology, and quality control assays. BioPROtect® enclosures are designed for aseptic product preparation and biological investigation involving agents of low to moderate risk. The BioPROtect® III may be exhausted back into the laboratory or connected to an in-house exhaust system. The BioPROtect® III model offers clean air offers clean air and biocontainment while allowing total access to the spacious 164-cubic foot interior work area (nominal) with combination double doors. The BioPROtect® III Jr. has a single door access with a 78-cubic foot interior volume.
General Specifications
There are no General Specifications available.
Series Modals
Baker - BPIII
[+] View Model SpecificationsAirflow (CFM) | 490 CFM when exhausted to room. 700 when exhausted through canopy exhaust |
Depth | 36.5 in |
Height | 76 in |
Width | 102 in |
Power Requirements | 120V |
Weight | 1100 lbs |
Shipping Weight | 1500 lbs |
Cabinet Type | Class II Type A2 |
Filter Type | HEPA |
Additional Model Specifications |
Baker - BPJr
[+] View Model SpecificationsAirflow (CFM) | 250 CFM when exhausted to room. 350 when exhausted through canopy exhaust |
Internal Depth | 36.5 in |
Internal Height | 76 in |
Internal Width | 49 in |
Power Requirements | 120V |
Weight | 800 lbs |
Shipping Weight | 1100 lbs |
Cabinet Type | Class II Type A2 |
Filter Type | HEPA |
Additional Model Specifications |