For accurate and reliable collection of small fractions

The Agilent 1260 Infinity Micro-fraction Collection/Spotting System for capillary and nanoflow rates (100 nL/min to 100 ΜL/min) is designed for collection of small fractions in 96 and 384 wellplate format, vials and Eppendorf tubes. It is capable of spotting nanoliter amounts reliably, precisely and fast onto MALDI targets of all major vendors. The unique liquid contact control mode for droplet deposition in combination with proprietary tip design of the outlet capillary guarantees reproducible deposition of even the smallest droplets without bubble formation or cross contamination.This feature ensures that even at lowest flow rates combined with fast spotting rates the droplets are exactly positioned where they need to be.
Active Questions & AnswersAsk a Question

There are no current Discussions

Preparative HPLC Service ProvidersView All (16)

Request Support
Features of 1260 Infinity Micro-scale
  • Micro-fraction collection 
  • Minimized delay volume and peak dispersion through optimized tubing sets 
  • Flow rate range from 100 nL/min to 100 ΜL/min (depending on pump) 
  • Back-pressure independent, best-in-class gradient reproducibility through electronic flow control 
  • High versatility through predefined well plate formats and Eppendorf tubes for up to 768 samples 
  • User-definable well plate choice for less common formats 
  • MALDI spotting 
  • Support for all major MALDI targets 
  • Easy to perform MALDI spotting calibration 
  • Fast spotting/collection rate (minimum 3 s/spot) 
  • Online matrix addition kit 
  • Thermostatted version for degradable bio-samples and to prevent or enhance fast evaporation of small fractions
General Specifications

There are no General Specifications available.

Additional Specifications

Agilent 1260 Infinity LC Micro Collection/Spotting System specifications 
 
Performance specs: 
Baseline noise: 
±3 × 10-5 AU, at 254 nm, at flow rates <100 µL/min 
System delay volume (typical): 
5 µL from EFC to column head, for flow rates up to 20 µL/min (default setup); 14 µL from EFC to column head, for flow rates up to 100 µl/min (default setup) 
System control: 
Through local computer software, LAN or local handheld control module 
GLP features: 
Early maintenance feedback—EMF 
(tracks lamp burn time, usage, number of injections with limits and feedback messages)