Tecan - Sunrise

Manufactured by  Tecan
Follow this Equipment

The smart & reliable microplate reader for ELISA assays & kinetics

Sunrise is a versatile microplate absorbance reader for 96-well plates providing all the functionality needed for the numerous applications in diagnostics, biotechnology and research laboratories.         
         
A set of options such as temperature control up to 42°C, a gradient filter for wavelengths scanning and a barcode scanner allow to customize the Sunrise to your application needs.         
         
The compact space saving design makes the Sunrise ideal for stand-alone use, as well as integration into automated ELISA-systems such as the Freedom EVOlyzer®.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Updated bydr.wo

Microplate Readers Service ProvidersView All (12)

Request Support
Features of Sunrise
  • Supports ELISA- & kinetics-, as well as agglutination reading         

  • Selection of user interface: Netbook* or Touchscreen         

  • Selection of eight languages for easy operation         

  • 3 year warranty as Tecan´s commitment to quality         

  • Reads plate in only 6 sec. via advanced 12-channel optics         

  • Powered by smart Magellan™ data analysis software         

  • Quick access to your program favourite via start-screen         

  • Advanced curve-fitting & plate-to-plate QC functions         

  • IQ / OQ procedure & documentation         

  • Designed to meet IVDD 98/79/EC & FDA´s 21 CFR part 11**         

  • Netbook not included.          ** Using Magellan Tracker software

General Specifications
Shaking1
Detection ModeAbsorbance
Shaking PatternLinear shaking in 4 different modes
Wavelength Range340 to 750 nm
Microplate Size96-well
SoftwareIntegrated
Temperature Control 1
Additional Specifications

Optical system: 12 measurement channels, 1 reference channel     
Wavelength selection: Interference filters (slide of 4 to 6 filters), Bandwidth: 10 nm     
Measurement range: 340 to 399 nm: 0 to 3.0 OD, 400 to 750 nm: 0 to 4.0 OD     
Measurement time:      
Single wavelength: 6 seconds     
Dual wavelength: 8 seconds     
Kinetic repeat time: 5 seconds     
Accuracy:      
0.0 to 2.0 OD/492 nm: better than ± (1.0% + 0.010 OD)     
2.0 to 3.0 OD/492 nm: better than ± (1.5% + 0.010 OD)     
Linearity:      
340 to 399 nm: 0.0 to 2.0 OD better than ±2%     
400 to 750 nm: 0.0 to 2.0 OD better than ±1%     
2.0 to 3.0 OD better than ±1.5%     
Precision:      
0.0 to 2.0 OD/492 nm: better than ± (0.5% + 0.005 OD)     
2.0 to 3.0 OD/492 nm: better than ± (1.0% + 0.005 OD)     
Resolution: 0.001 OD     
Interface: RS 232 C/USB