DESCRIPTION
Benchtop Analyzer

Thermo Scientific* MGC 240 Benchtop Analyzer meets the marketplace need for an open, flexible system.      Capable of running 240 tests per hour and handling up to 24, two-reagent immunoassays per run, the Thermo Scientific MGC 240 Benchtop Analyzer can be used for your drugs of abuse screens and therapeutic drug monitoring, including your immunosuppressive diagnostic assays and specimen validity tests.

FEATURES

   Features   • Largest menu of tests available   • Compact benchtop analyzer   • Broad menu of immunoassays with multiple technology options   • Multiple channels: up to 24 two-reagent tests   • High throughput: 240 tests/hour   • 24-hour reagent cooling   • Bar coding capabilities      Functions   • Random access, true STAT interrupt capability   • Adapts to various primary tubes and sample cups   • Automatic cuvette QC   • Auto rerun, auto dilution, sample pre-dilution   • Re-suspension mixing for latex particles   • Auto alarms for washing and waste containers   • Air pressure mixing: no carry over      Software   • Windows based technology   • Reagent/test volume inventory display   • User-friendly intuitive operator interface   • Run-monitor displays test results wait time   • Bi-directional interface for LIS systems   • Host query communications      Cuvettes   • Unique design   • Easy maintenance   • Distinctive air pressure mixing system: no mixing paddles   • No carry over: fewer washing steps   • Semi-permanent: replace 1 to 2 times per year  

SPECIFICATIONS
Advertisement
QUESTIONS & ANSWERS

1

Answer
-ratgurl
5 years ago
MGC 240 same as Biolis 24i?
I run a small lab, testing about 40 DOA samples per week on a Biolis 24i. From the images provided, the MGC240 appears to be nearly identical. Does anyone know if these are in fact the same instrument? Any input is appreciated.

Reply

0

Answers
-Graig
6 years ago
LIS communication
We have 2 MGC240s and they are currently linked using QuickLabs LIS. We have been trying to break that connection in favor of interfacing directly with our LIS, through a DI interface.

I made all the setting adjustments needed, as described in their bi-direction communication specification, but received "run time error 6: overflow" when attempting to send data to our system.

Any ideas on how to make the connection successful?

Reply

0

Answers
-JessL
6 years ago
Barcode Not reading
I have a MGC 240 that is not reading the barcodes. How do I fix this?

Reply

Ask a Question

Ask anything about
Thermo Scientific - MGC 240